{"created":"2023-07-27T06:25:39.934874+00:00","id":9056,"links":{},"metadata":{"_buckets":{"deposit":"f745c4e6-f783-4a86-9eb1-3f595f9138c1"},"_deposit":{"created_by":3,"id":"9056","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9056"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009056","sets":["934:935:936"]},"author_link":["10422","12884","12883"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"1441","bibliographicPageStart":"1437","bibliographicVolumeNumber":"71","bibliographic_titles":[{"bibliographic_title":"Journal of the Japan Society for Precision Engineering, Contributed Papers = 精密工学会誌論文集"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The temperature on the rake face of a binder-less cBN tool tip in end-milling was measured using a fiber-optic two-color pyrometer. The radiation of the interface between the tool tip and the chip is transmitted through the binder-less cBN and accepted by the optical fiber located behind the tool tip. The radiation accepted is transmitted to a two-color detector, which consists of a InAs and InSb detector, through a rotary fiber coupler. The coupler makes it possible to transmit the radiation outside the milling machine. The fundamental transmission characteristics of the coupler was investigated theoretically and experimentally. This method was found to be very practical to measure the tool tip temperature in end-milling. The results obtained are as follows. The rake face temperature in the up-milling of 0.55% carbon steel ranged from 480 degrees centigrade to 560 degrees centigrade for the cutting speeds of 2.2 m/s to 4.4 m/s. The cutting temperature increases with the increase of cutting speed. The temperature in down-milling is higher a little than that in the up-milling. バインダレスcBNによるエンドミル加工時の工具刃先温度を光ファイバ型2色温度計を用いて測定している. 工具すくい面から放射される赤外線を工具裏面から受光し, 2本の光ファイバを連結する回転型ファイバカプラを介して伝送することにより, 高速回転している刃先の温度測定を可能にしている. 切削速度や切削方式の相違が刃先温度に及ぼす影響について検討している.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会 = The Japan Society for Precision Engineering"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2493/jspe.71.1437","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jspe.or.jp/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jspe","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/10016764424/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2007 The Japan Society for Precision Engineering 精密工学会"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA11966630","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1348-8724","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐藤, 昌彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"上田, 隆司"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"田中, 久隆"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-UEDA-T-1437.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-UEDA-T-1437.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9056/files/TE-PR-UEDA-T-1437.pdf"},"version_id":"b745af70-d3b2-44b3-b01c-29688ecf88b8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ファイバ連結型熱放射温度計によるバインダレスcBNエンドミル加工温度の測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ファイバ連結型熱放射温度計によるバインダレスcBNエンドミル加工温度の測定"},{"subitem_title":"Measurement of Binder-Less cBN Tool Tip Temperature in End-Milling using Thermal Radiation Pyrometer Connected by Rotary Fiber Coupler","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9056","relation_version_is_last":true,"title":["ファイバ連結型熱放射温度計によるバインダレスcBNエンドミル加工温度の測定"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T01:59:46.566302+00:00"}