{"created":"2023-07-27T06:25:45.505686+00:00","id":9188,"links":{},"metadata":{"_buckets":{"deposit":"55894e73-8ea8-4e8c-8ceb-6b8f52a343c4"},"_deposit":{"created_by":3,"id":"9188","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9188"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009188","sets":["4163:4171:4187"]},"author_link":["13115","131","13118","11438","10208","12158","13116","109834","109833","13117","109832","109835"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-01-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"821","bibliographicPageStart":"14-00133","bibliographicVolumeNumber":"81","bibliographic_titles":[{"bibliographic_title":"日本機械学会論文集 = Transactions of the JSME"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tachiya, Hiroshi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Uchiyama, Daisaku"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Motoya, Tatsuro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tsuruoka, Muneharu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Fujita, Keigo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Miyazaki, Yusuke"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Falls are a major reason for elderly people to require nursing care. Prevention of falls requires evaluation of standing balance ability of human. Thus various measurements were performed and the relation between the results and occurrence of falls was considered. Although these measurements were mainly done under stable upright posture, the measurements of balance ability should be done under near falling. However, from a viewpoint of safety of subjects, the occurrences of falls which may inflict damage on them must be avoided during the measurements. This study, thus, develops a device that can measure standing balance of subjects until falls. The device consists of a three degree of freedom (3DOF) wire driven parallel mechanism, the output link of which is attached to a subject. The device can control 3DOF rotational motion of the output link by wires. Each wire has strain-gages to detect the forces applied to the output link and judge the falling moment. Furthermore, a force-plate is set on the base to measure the center of pressure (COP) of a subject. The device can guide subjects in specified direction at the measurement and support them safely at falling. We measured the COP at the fall moment and the body sways on tilting posture by the proposed device. As a result, it is found that the differences between subjects become clearer as their postures tilt closer to fall moment.","subitem_description_type":"Abstract"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学高度モビリティ研究所 / 金沢大学理工研究域機械工学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00009175","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会 The Japan Society of Mechanical Engineers"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1299/transjsme.14-00133","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/transjsme/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.jsme.or.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 2015 The Japan Society of Mechanical Engineers"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-9761","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"立矢, 宏"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"内島, 大作"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"元谷, 達郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鶴岡, 宗治"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤田, 圭伍"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"宮崎, 祐介"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-TACHIYA-H-00133.pdf","filesize":[{"value":"932.7 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-TACHIYA-H-00133.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9188/files/TE-PR-TACHIYA-H-00133.pdf"},"version_id":"ec49e79e-a9ac-4af9-8536-6329de9e554d"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"パラレルワイヤ駆動機構を用いた立位バランス能力の測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"パラレルワイヤ駆動機構を用いた立位バランス能力の測定"},{"subitem_title":"Measurement of standing balance ability by a wire driven parallel mechanism","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["4187"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9188","relation_version_is_last":true,"title":["パラレルワイヤ駆動機構を用いた立位バランス能力の測定"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T10:15:38.734625+00:00"}