{"created":"2023-07-27T06:25:50.256853+00:00","id":9299,"links":{},"metadata":{"_buckets":{"deposit":"5e620d10-2c62-4cee-95b0-a057eb87bfd3"},"_deposit":{"created_by":3,"id":"9299","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9299"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009299","sets":["934:935:936"]},"author_link":["327","13307"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"344","bibliographicPageStart":"337","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"Journal of Agricultural Meteorology = 農業気象"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A theoretical analysis of an operation of extraction and accumulation of the heat generated in composting process by water circulation was made. The calculated results of the average temperature in a compost bed and the water temperature in an accumulator were compared with the experimental results obtained previously. 1) For the case of the intermittent water-circulation, there were slight differences between the calculated results and the experimental results of the average temperature in the bed during temperature recovering periods after the end of water-circulation. However, the calculated results of the water temperature in the accumulator, the available time for heat extraction and the recovery time of temperature in the bed agreed relatively well with the experimental results. The theoretical model was fairly fit for this case. 2) For the case of the continuous water-circulation, the calculated results of the average temperature in the bed were in fair agreement with the experimental results. The calculated results of the water temperature in the accumulator were however 3 to 7 degrees higher than the experimental results. It could be due to the heat loss through the pipes connecting the container for the compost with the accumulator, which was not allowed for in the theoretical model. It is necessary to modify the analytical model by taking account of this kind of heat loss.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本農業気象学会 = Society of Agricultural Meteorology of Japan"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2480/agrmet.41.337","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/agrmet","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://agrmet.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © The Society of Agricultural Meteorology of Japan"}]},"item_4_rights_24":{"attribute_name":"権利URI","attribute_value_mlt":[{"subitem_rights":"http://www.agrmet.jp/"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA12492451","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0021-8588","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"関, 平和"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"小森, 友明"}],"nameIdentifiers":[{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-SEKI-H-337.pdf","filesize":[{"value":"935.6 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-SEKI-H-337.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9299/files/TE-PR-SEKI-H-337.pdf"},"version_id":"9c755375-c4fb-4df6-bbf2-91e2e44674bd"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"堆肥発酵熱の抽出・蓄積に関する研究: 第2報 循環通水方式による熱抽出・蓄熱過程の理論解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"堆肥発酵熱の抽出・蓄積に関する研究: 第2報 循環通水方式による熱抽出・蓄熱過程の理論解析"},{"subitem_title":"A Study of Extraction and Accumulation of the Heat Generated in Composting Process: Part 2. A Theoretical Analysis of Heat Extraction and Accumulation Process by Water Circulation","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9299","relation_version_is_last":true,"title":["堆肥発酵熱の抽出・蓄積に関する研究: 第2報 循環通水方式による熱抽出・蓄熱過程の理論解析"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-07-28T01:56:30.434368+00:00"}