{"created":"2023-07-27T06:25:55.607907+00:00","id":9427,"links":{},"metadata":{"_buckets":{"deposit":"a84d691e-e4d0-4c4f-b63d-84b761844c5c"},"_deposit":{"created_by":3,"id":"9427","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9427"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009427","sets":["934:935:936"]},"author_link":["2757","13567","13568"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-09-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"691","bibliographicPageEnd":"1988","bibliographicPageStart":"1981","bibliographicVolumeNumber":"78","bibliographic_titles":[{"bibliographic_title":"日本建築学会計画系論文集 = Journal of Architecture and Planning (Transactions of AIJ)"}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper studies on influences by setback regulation and height control to building activities through simulating using building form models which satisfy relating regulations in a case of residential zoning area. As result of the study it is clarified that the combination of building form and site figure which could satisfy most easily the setback regulations is oblong in the depth direction and their layout possible range becomes smaller according to the bigger designated floor area ratio (FAR) because its building coverage ratio also becomes bigger. Height control 12m in area of 200% FAR and 15m in area of 300% FAR are easily satisfied and these height control would be effective to realize better landscape using with the setback regulation.","subitem_description_type":"Abstract"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会 = Architectural Institute of Japan"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3130/aija.78.1981","subitem_relation_type_select":"DOI"}}]},"item_4_relation_28":{"attribute_name":"関連URI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/aija/-char/ja/","subitem_relation_type_select":"URI"}},{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.aij.or.jp/","subitem_relation_type_select":"URI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © 日本建築学会 Architectural Institute of Japan"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438548","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1340-4210","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"川上, 光彦"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"大西, 宏樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"藤田, 和也"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-KAWAKAMI-M-1981.pdf","filesize":[{"value":"5.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"TE-PR-KAWAKAMI-M-1981.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9427/files/TE-PR-KAWAKAMI-M-1981.pdf"},"version_id":"6a03fd61-f103-4044-a563-ca5558c65d47"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"中高層建築物の建築行為に対する斜線制限および高さ規制による影響: 住居系用途地域の場合","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"中高層建築物の建築行為に対する斜線制限および高さ規制による影響: 住居系用途地域の場合"},{"subitem_title":"Study on impact by setback regulation and height control to the building activities of mid-to-high-rise building: Case study of residential land-use zoning district","subitem_title_language":"en"}]},"item_type_id":"4","owner":"3","path":["936"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9427","relation_version_is_last":true,"title":["中高層建築物の建築行為に対する斜線制限および高さ規制による影響: 住居系用途地域の場合"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T15:04:40.809174+00:00"}