@article{oai:kanazawa-u.repo.nii.ac.jp:00009554, author = {Yamada, Sotoshi and Katou, M. and Iwahara, Masayoshi and Dawson, F.P.}, issue = {6}, journal = {IEEE Transactions on Maggetics}, month = {Aug}, note = {This paper presents results pertaining to image data obtained from a planar meander-mesh coupled coil type ECT probe. The image data makes it possible to detect not only the existence of a defect but also to extract detailed information regarding the nature of the defect, such as its position, shape, length, and direction. In order to recognize a defect distinctly, we have fabricated the high sensitive planar coil which can be used to image a 2-D representation of the ECT signal. The relationships between the image pattern and defect shape are discussed.}, pages = {4956--4958}, title = {Defect Images by Planar ECT Probe of Meander-Mesh Coils}, volume = {32}, year = {1996} }