{"created":"2023-07-27T06:26:01.019364+00:00","id":9556,"links":{},"metadata":{"_buckets":{"deposit":"a4ac4e1b-c90a-425e-8855-aa0e03f53fe3"},"_deposit":{"created_by":3,"id":"9556","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9556"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009556","sets":["4193:4194:4195"]},"author_link":["68771","146"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09-15","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"388","bibliographicPageStart":"377","bibliographicVolumeNumber":"111","bibliographic_titles":[{"bibliographic_title":"Energy"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"山本, 茂"}],"nameIdentifiers":[{},{},{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper proposes a new method for obtaining the maximum power output of a doubly fed induction generator (DFIG) wind turbine. This scheme does not require the precise parameters of the wind turbine or any information about the wind speed or wind sensor. The maximum power point tracking (MPPT) ability of the proposed method is theoretically proven under some certain assumptions. To obtain the required control performance, several control parameters may be adopted. Particularly, the control method is constructed on the basis of the Lyapunov function. The quality of the proposed method is verified by the numerical simulation of a 1.5-MW DFIG wind turbine. The simulation results show that the wind turbine implemented with the proposed method can track the optimal operation point. Furthermore, the energy output of the DFIG wind turbine using the proposed method is higher compared to conventional methods under the same conditions. © 2016 Elsevier Ltd","subitem_description_type":"Abstract"}]},"item_4_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Embargo Period 24 months","subitem_description_type":"Other"}]},"item_4_description_5":{"attribute_name":"提供者所属","attribute_value_mlt":[{"subitem_description":"金沢大学融合研究域融合科学系","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00009543","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.energy.2016.05.077","subitem_relation_type_select":"DOI"}}]},"item_4_rights_23":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright © Elsevier (CC-BY NC ND)"}]},"item_4_source_id_11":{"attribute_name":"NCID","attribute_value_mlt":[{"subitem_source_identifier":"AA00635303","subitem_source_identifier_type":"NCID"}]},"item_4_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0360-5442","subitem_source_identifier_type":"ISSN"}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Phan, Dinh-Chung"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamamoto, Shigeru"}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-09-16"}],"displaytype":"detail","filename":"TE-PR-YAMAMOTO-S-377.pdf","filesize":[{"value":"968.1 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-YAMAMOTO-S-377.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9556/files/TE-PR-YAMAMOTO-S-377.pdf"},"version_id":"7b5f9f45-bc7c-48fb-bfbf-b73746f919d9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Rotor speed control of doubly fed induction generator wind turbines using adaptive maximum power point tracking","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Rotor speed control of doubly fed induction generator wind turbines using adaptive maximum power point tracking"}]},"item_type_id":"4","owner":"3","path":["4195"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-12-05"},"publish_date":"2017-12-05","publish_status":"0","recid":"9556","relation_version_is_last":true,"title":["Rotor speed control of doubly fed induction generator wind turbines using adaptive maximum power point tracking"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T10:23:00.299668+00:00"}