{"created":"2023-07-27T06:26:02.111839+00:00","id":9582,"links":{},"metadata":{"_buckets":{"deposit":"31139917-c68a-4b8c-ac81-d305f7c73a63"},"_deposit":{"created_by":3,"id":"9582","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9582"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009582","sets":["2438:4190:4191"]},"author_link":["1669","1758","12199","119","217","13874","13875","9863","154","11685"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-08-25","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"150","bibliographicPageStart":"145","bibliographicVolumeNumber":"2015-August","bibliographic_titles":[{"bibliographic_title":"Proceedings of the IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM)"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"米山, 猛"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"香川, 博之"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"林, 裕"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"中田, 光俊"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"渡辺, 哲陽"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A silicone retractor that can be attached to suction pipes was developed in order to enhance the usability [1]. The measurement of the retracting force is desired in order to avoid damage to brain tissue due to an unexpected large force. This paper presents a force-sensing embedded silicone retractor that can be attached to suction pipes. The developed silicone retractor can provide three functions at the same time: suction, retracting, and retracting force measurement. The force-sensing system is based on a visualization mechanism that displays the force as a colored pole motion. The surgeon can then roughly estimate the retracting force. With a fiberscope, the retracting force can be measured with a resolution of 0.05-0.3 N. The retractor is made of silicone and has the advantages of disposability, low cost, and easy sterilization/disinfection. The system was validated through finite element method analysis and experiments. © 2015 IEEE.","subitem_description_type":"Abstract"}]},"item_4_description_22":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"IEEE/ASME International Conference on Advanced Intelligent Mechatronics, AIM 2015; BEXCOBusan; South Korea; 7 July 2015 through 11 July 2015; Category numberCFP15775-ART; Code 117136","subitem_description_type":"Other"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00009569","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers Inc."}]},"item_4_relation_10":{"attribute_name":"ISBN","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"978-146739107-8","subitem_relation_type_select":"ISBN"}}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/AIM.2015.7222523","subitem_relation_type_select":"DOI"}}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koyama, Toshio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iwai, Takanobu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoneyama, Takeshi"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Kagawa, Hiroyuki"}],"nameIdentifiers":[{},{},{},{}]},{"creatorNames":[{"creatorName":"Hayashi, Yutaka"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Nakada, Mitsutoshi"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"Watanabe, Tetsuyou"}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-WATANABE-T-145.pdf","filesize":[{"value":"767.0 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-WATANABE-T-145.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9582/files/TE-PR-WATANABE-T-145.pdf"},"version_id":"3dd0e53d-b85c-4f85-b3c1-4961ee18d957"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Silicone retractor with embedded force-sensing function for attachment to surgical suction pipes","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Silicone retractor with embedded force-sensing function for attachment to surgical suction pipes"}]},"item_type_id":"4","owner":"3","path":["4191"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9582","relation_version_is_last":true,"title":["Silicone retractor with embedded force-sensing function for attachment to surgical suction pipes"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T10:30:44.694446+00:00"}