{"created":"2023-07-27T06:26:02.153895+00:00","id":9583,"links":{},"metadata":{"_buckets":{"deposit":"31fa4b19-c76a-404c-96a7-46cca75c0531"},"_deposit":{"created_by":3,"id":"9583","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9583"},"status":"published"},"_oai":{"id":"oai:kanazawa-u.repo.nii.ac.jp:00009583","sets":["2438:4190:4191"]},"author_link":["1669","13878","13877","12199","9863","13876","154"],"item_4_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2016","bibliographicPageEnd":"1404","bibliographicPageStart":"1398","bibliographic_titles":[{"bibliographic_title":"Proceedings of the IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM)"}]}]},"item_4_creator_33":{"attribute_name":"著者別表示","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"米山, 猛"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"中田, 光俊"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"渡辺, 哲陽"}],"nameIdentifiers":[{},{}]}]},"item_4_description_21":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper presents a silicone retractor, which is a continuation and extension of a previously developed system that had the same three functions as the old version: 1) retracting, 2) suction, and 3) force sensing. These features make the retractor a safe choice for use in neurosurgery. Suction is achieved by attaching the retractor to a suction pipe. The retractor has a deformation area filled with an incompressible liquid that is displaced in proportion to the extent of deformation; fiberscopes or human eyes detecting the displacement get a visual representation of the force. The new design improves on the old one in three ways—miniaturization, made possible by the incompressible-liquid-based mechanism, and measurement of force distribution by distribution of the areas deformed by force. The system was validated by conducting experiments.","subitem_description_type":"Abstract"}]},"item_4_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24517/00009570","subitem_identifier_reg_type":"JaLC"}]},"item_4_publisher_17":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Institute of Electrical and Electronics Engineers Inc."}]},"item_4_relation_12":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/aim.2016.7576966","subitem_relation_type_select":"DOI"}}]},"item_4_version_type_25":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koyama, Toshio"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yoneyama, Takeshi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Nakada, Mitsutoshi"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"Watanabe, Tetsuyou"}],"nameIdentifiers":[{},{},{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-03"}],"displaytype":"detail","filename":"TE-PR-WATANABE-T-1398.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"TE-PR-WATANABE-T-1398.pdf","url":"https://kanazawa-u.repo.nii.ac.jp/record/9583/files/TE-PR-WATANABE-T-1398.pdf"},"version_id":"517abe99-6d04-4bd4-89b2-9d4632201a26"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Incompressible Liquid Based Force Sensible Silicone Retractor Attachable to Surgical Suction Instruments","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Incompressible Liquid Based Force Sensible Silicone Retractor Attachable to Surgical Suction Instruments"}]},"item_type_id":"4","owner":"3","path":["4191"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-10-03"},"publish_date":"2017-10-03","publish_status":"0","recid":"9583","relation_version_is_last":true,"title":["Incompressible Liquid Based Force Sensible Silicone Retractor Attachable to Surgical Suction Instruments"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-07-27T10:30:40.678762+00:00"}