WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "bcc32adf-992e-4cfb-bf5c-b3529bc206d8"}, "_deposit": {"created_by": 3, "id": "13728", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13728"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013728", "sets": ["1134"]}, "author_link": ["120"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "6", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "30", "bibliographic_titles": [{"bibliographic_title": "医用画像情報学会雑誌 = Medical Imaging and Information Sciences"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "I talked about how to noninvasively obtain the hydrodynamic and biomechanical properties of the brain using magnetic resonance imaging (MRI) , and how to apply them clinically. I first described an analytical method for intracranial compliance using phase contrast MRI to assess the intracranial condition and hydrodynamics and to assist in the diagnosis of idiopathic normal pressure hydrocephalus (iNPH) . Next, I showed a novel method called “fluctuation MRI” for evaluating hydrodynamic and biomechanical properties of the brain obtained with the regional water-molecular diffusion change during the cardiac cycle. I explained the basis of this method and its clinical applications.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.11318/mii.30.1", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/mii/-char/ja/", "subitem_relation_type_select": "URI"}}, {"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.mii-sci.jp/", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10156808", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-1543", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "宮地, 利明"}], "nameIdentifiers": [{"nameIdentifier": "120", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=80324086"}, {"nameIdentifier": "80324086", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080324086"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-MIYATI-T-1.pdf", "filesize": [{"value": "2.8 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2800000.0, "url": {"label": "ME-PR-MIYATI-T-1.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13728/files/ME-PR-MIYATI-T-1.pdf"}, "version_id": "5f326d63-2e4e-4638-976a-4a6c259ba731"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Magnetic Resonance Image (MRI)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Compliance", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Intracranial Pressure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Diffusion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "normal pressure hydrocephalus", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "MRIで脳を測る", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "MRIで脳を測る"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/39280", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13728", "relation": {}, "relation_version_is_last": true, "title": ["MRIで脳を測る"], "weko_shared_id": -1}
MRIで脳を測る
http://hdl.handle.net/2297/39280
http://hdl.handle.net/2297/39280008fbb1c-c30c-410f-b082-21872dfd2f08
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-MIYATI-T-1.pdf (2.8 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | MRIで脳を測る | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
宮地, 利明
× 宮地, 利明 |
|||||
書誌情報 |
医用画像情報学会雑誌 = Medical Imaging and Information Sciences 巻 30, 号 1, p. 1-6, 発行日 2013-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-1543 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10156808 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.11318/mii.30.1 | |||||
出版者 | ||||||
出版者 | 医用画像情報学会 = MII: Japan Society of Medical Imaging and Information Sciences | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | I talked about how to noninvasively obtain the hydrodynamic and biomechanical properties of the brain using magnetic resonance imaging (MRI) , and how to apply them clinically. I first described an analytical method for intracranial compliance using phase contrast MRI to assess the intracranial condition and hydrodynamics and to assist in the diagnosis of idiopathic normal pressure hydrocephalus (iNPH) . Next, I showed a novel method called “fluctuation MRI” for evaluating hydrodynamic and biomechanical properties of the brain obtained with the regional water-molecular diffusion change during the cardiac cycle. I explained the basis of this method and its clinical applications. | |||||
権利 | ||||||
権利情報 | Copyright © 医用画像情報学会 MII: Japan Society of Medical Imaging and Information Sciences | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/mii/-char/ja/ | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.mii-sci.jp/ |