WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "fab6dc6e-23e8-40bf-8a79-c3b49e354037"}, "_deposit": {"created_by": 3, "id": "13789", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "13789"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00013789", "sets": ["4312"]}, "author_link": ["23188", "299", "23185", "3018", "21909", "23184", "646", "13121", "23186", "2896"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-01-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "PART 3", "bibliographicPageStart": "76224S", "bibliographicVolumeNumber": "7622", "bibliographic_titles": [{"bibliographic_title": "Progress in Biomedical Optics and Imaging - Proceedings of SPIE"}]}]}, "item_4_creator_33": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "田中, 利恵"}], "nameIdentifiers": [{"nameIdentifier": "299", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040361985"}]}, {"creatorNames": [{"creatorName": "市川, 勝弘"}], "nameIdentifiers": [{"nameIdentifier": "646", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040402630"}]}, {"creatorNames": [{"creatorName": "川嶋, 広貴 "}], "nameIdentifiers": [{"nameIdentifier": "3018", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70775577", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70775577"}]}, {"creatorNames": [{"creatorName": "真田, 茂"}], "nameIdentifiers": [{"nameIdentifier": "2896", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50020029"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "There is a concern that image lag may reduce accuracy of real-time target tracking in radiotherapy. This study was performed to investigate influence of image lag on the accuracy of target tracking in radiotherapy. Fluoroscopic image: were obtained using a direct type of dynamic flat-panel detector (FPD) system under conditions of target tracking during radiotherapy. The images continued to be read out after X-irradiations and cutoff, and image lag properties in the system were then determined. Subsequently, a tungsten materials plate with a precision edge was mounted on to a motor control device, which provided a constant velocity. The plate was moved into the center of the detector at movement rate of 1 and 20 mm/s, covering lung tumor movement of normal breathing, and MTF and profile curves were measured on the edges covering and uncovering the detector. A lung tumor with blurred edge due to image lag was simulated using the results and then superimposed on breathing chest radiographs of a patient. The moving target with and without image lag was traced using a template-matching technique. In the results, the target could be traced within a margin for error ii external radiotherapy. The results indicated that there was no effect of image lag on target tracking in usual breathing speed in a radiotherapy situation. Further studies are required to investigate influence by the other factors, such a: exposure dose, target size and shape, imaging rate, and thickness of a patient\u0027s body. © 2010 SPIE.", "subitem_description_type": "Abstract"}]}, "item_4_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00013776", "subitem_identifier_reg_type": "JaLC"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Society of Photo-optical Instrumentation Engineers (SPIE)"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1117/12.844202", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_24": {"attribute_name": "権利URI", "attribute_value_mlt": [{"subitem_rights": "http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=747539"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1605-7422", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tanaka, Rie"}], "nameIdentifiers": [{"nameIdentifier": "299", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40361985"}, {"nameIdentifier": "40361985", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040361985"}]}, {"creatorNames": [{"creatorName": "Ichikawa, Katsuhiro"}], "nameIdentifiers": [{"nameIdentifier": "646", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040402630"}]}, {"creatorNames": [{"creatorName": "Mori, Shinichiro"}], "nameIdentifiers": [{"nameIdentifier": "23184", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Dobashi, Suguru"}], "nameIdentifiers": [{"nameIdentifier": "23185", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumagaya, Motoki"}], "nameIdentifiers": [{"nameIdentifier": "23186", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawashima, Hiroki"}], "nameIdentifiers": [{"nameIdentifier": "21909", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70775577", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=70775577"}]}, {"creatorNames": [{"creatorName": "Morita, Shinichi"}], "nameIdentifiers": [{"nameIdentifier": "23188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sanada, Shigeru"}], "nameIdentifiers": [{"nameIdentifier": "13121", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=50020029"}, {"nameIdentifier": "50020029", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000050020029"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-TANAKA-R-76224S.PDF", "filesize": [{"value": "442.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 442800.0, "url": {"label": "ME-PR-TANAKA-R-76224S.PDF", "url": "https://kanazawa-u.repo.nii.ac.jp/record/13789/files/ME-PR-TANAKA-R-76224S.PDF"}, "version_id": "07fd86ce-035e-46f7-a355-00bb1e3d8ecf"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Flat panel detector", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Image lag", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Radiotherapy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Target tracking", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effects of image lag on real-time target tracking in radiotherapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effects of image lag on real-time target tracking in radiotherapy"}]}, "item_type_id": "4", "owner": "3", "path": ["4312"], "permalink_uri": "https://doi.org/10.24517/00013776", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "13789", "relation": {}, "relation_version_is_last": true, "title": ["Effects of image lag on real-time target tracking in radiotherapy"], "weko_shared_id": 3}
Effects of image lag on real-time target tracking in radiotherapy
https://doi.org/10.24517/00013776
https://doi.org/10.24517/0001377667677248-8104-4660-b083-dcd374780779
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-TANAKA-R-76224S.PDF (442.8 kB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Effects of image lag on real-time target tracking in radiotherapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
ID登録 | ||||||
ID登録 | 10.24517/00013776 | |||||
ID登録タイプ | JaLC | |||||
著者 |
Tanaka, Rie
× Tanaka, Rie× Ichikawa, Katsuhiro× Mori, Shinichiro× Dobashi, Suguru× Kumagaya, Motoki× Kawashima, Hiroki× Morita, Shinichi× Sanada, Shigeru |
|||||
著者別表示 |
田中, 利恵
× 田中, 利恵× 市川, 勝弘× 川嶋, 広貴× 真田, 茂 |
|||||
書誌情報 |
Progress in Biomedical Optics and Imaging - Proceedings of SPIE 巻 7622, 号 PART 3, p. 76224S, 発行日 2010-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1605-7422 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1117/12.844202 | |||||
出版者 | ||||||
出版者 | Society of Photo-optical Instrumentation Engineers (SPIE) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | There is a concern that image lag may reduce accuracy of real-time target tracking in radiotherapy. This study was performed to investigate influence of image lag on the accuracy of target tracking in radiotherapy. Fluoroscopic image: were obtained using a direct type of dynamic flat-panel detector (FPD) system under conditions of target tracking during radiotherapy. The images continued to be read out after X-irradiations and cutoff, and image lag properties in the system were then determined. Subsequently, a tungsten materials plate with a precision edge was mounted on to a motor control device, which provided a constant velocity. The plate was moved into the center of the detector at movement rate of 1 and 20 mm/s, covering lung tumor movement of normal breathing, and MTF and profile curves were measured on the edges covering and uncovering the detector. A lung tumor with blurred edge due to image lag was simulated using the results and then superimposed on breathing chest radiographs of a patient. The moving target with and without image lag was traced using a template-matching technique. In the results, the target could be traced within a margin for error ii external radiotherapy. The results indicated that there was no effect of image lag on target tracking in usual breathing speed in a radiotherapy situation. Further studies are required to investigate influence by the other factors, such a: exposure dose, target size and shape, imaging rate, and thickness of a patient's body. © 2010 SPIE. | |||||
権利URI | ||||||
権利情報 | http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=747539 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |