WEKO3
インデックスリンク
アイテム
Rapid detection of human immunodeficiency virus type 1 group M by a reverse transcription-loop-mediated isothermal amplification assay
http://hdl.handle.net/2297/17332
http://hdl.handle.net/2297/1733214d757f1-0823-4713-8592-50a2f92abcef
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Rapid detection of human immunodeficiency virus type 1 group M by a reverse transcription-loop-mediated isothermal amplification assay | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hosaka, Norimitsu
× Hosaka, Norimitsu× Ndembi, Nicaise× Ishizaki, Azumi× Kageyama, Seiji× Numazaki, Kei× Ichimura, Hiroshi |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域医学系 | |||||
書誌情報 |
Journal of Virological Methods 巻 157, 号 2, p. 195-199, 発行日 2009-05-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0166-0934 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00259584 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.jviromet.2009.01.004 | |||||
出版者 | ||||||
出版者 | Elsevier BV | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A rapid one-step reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assay targeting the pol-integrase gene was developed to detect human immunodeficiency virus type 1 (HIV-1) group M. This HIV-1 RT-LAMP assay is simple and rapid, and amplification can be completed within 35 min under isothermal conditions at 60 °C. The 100% detection limit of HIV-1 RT-LAMP was determined using a standard strain (WHO HIV-1 [97/656]) in octuplicate and found to be 120 copies/ml. The RT-LAMP assay was evaluated for use for clinical diagnosis using plasma samples collected from 57 HIV-1-infected and 40 uninfected individuals in Cameroon, where highly divergent HIV-1 strains are prevalent. Of the 57 samples from infected individuals, 56 harbored group-M HIV-1 strains, such as subtypes A, B, G, F2, and circulating recombinant forms (CRFs) _01, _02, _09, _11, _13; all were RT-LAMP positive. One sample harboring group-O HIV-1 and the 40 HIV-1-uninfected samples were RT-LAMP negative. These findings indicate that HIV-1 RT-LAMP can detect HIV-1 group-M RNA from plasma samples rapidly and with high sensitivity and specificity. These data also suggest that this RT-LAMP assay can be useful for confirming HIV diagnosis, particularly in resource-limited settings. © 2009 Elsevier B.V. All rights reserved. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/01660934 |