{"_buckets": {"deposit": "32a95e51-fa4e-46d4-8a77-250dd2876945"}, "_deposit": {"created_by": 3, "id": "9613", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "9613"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00009613", "sets": ["936"]}, "author_link": ["13958", "11069", "11068"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-10-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "3804", "bibliographicPageStart": "3802", "bibliographicVolumeNumber": "41", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Maggetics"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Many applications of the single-axis controlled repulsive-type magnetic bearing have been proposed earlier. However, both passive and active magnetic bearings are employed in most of such systems. In this paper, a new permanent magnet (PM) repulsive-type micromass measurement system is developed. The repulsive forces of the PM section are used effectively to keep the radial direction stable where the electromagnets, control circuits, and peripheral devices needed for controlling the unstable direction are simplified. The configuration, control design, and operating characteristics of the proposed system have been presented.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Institute of Electrical and Electronics Engineers IEEE"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/TMAG.2005.854929", "subitem_relation_type_select": "DOI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2005 IEEE."}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00667933", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hussien, A.A."}], "nameIdentifiers": [{"nameIdentifier": "13958", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Sotoshi"}], "nameIdentifiers": [{"nameIdentifier": "11069", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=80019786"}, {"nameIdentifier": "80019786", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080019786"}]}, {"creatorNames": [{"creatorName": "Iwahara, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "11068", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "80020212", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000080020212"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "TE-PR-YAMADA-S-254.pdf", "filesize": [{"value": "423.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 423300.0, "url": {"label": "TE-PR-YAMADA-S-254.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/9613/files/TE-PR-YAMADA-S-254.pdf"}, "version_id": "7ab35ebe-1a43-4483-afba-2aeb4030e148"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Balance system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Control design", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Magnetic bearing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mass measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Permanent magnet repulsive force", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Application of the Repulsive-Type Magnetic Bearing for Manufacturing Micromass Measurement Balance Equipment", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Application of the Repulsive-Type Magnetic Bearing for Manufacturing Micromass Measurement Balance Equipment"}]}, "item_type_id": "4", "owner": "3", "path": ["936"], "permalink_uri": "http://hdl.handle.net/2297/48335", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "9613", "relation": {}, "relation_version_is_last": true, "title": ["Application of the Repulsive-Type Magnetic Bearing for Manufacturing Micromass Measurement Balance Equipment"], "weko_shared_id": -1}
Application of the Repulsive-Type Magnetic Bearing for Manufacturing Micromass Measurement Balance Equipment
http://hdl.handle.net/2297/48335
http://hdl.handle.net/2297/483358c81ea78-0d61-47c7-aafb-a4ead43b335c
名前 / ファイル | ライセンス | アクション |
---|---|---|
TE-PR-YAMADA-S-254.pdf (423.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Application of the Repulsive-Type Magnetic Bearing for Manufacturing Micromass Measurement Balance Equipment | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hussien, A.A.
× Hussien, A.A.× Yamada, Sotoshi× Iwahara, Masayoshi |
|||||
書誌情報 |
IEEE Transactions on Maggetics 巻 41, 号 10, p. 3802-3804, 発行日 2005-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9464 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00667933 | |||||
DOI | ||||||
関連タイプ | isIdenticalTo | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TMAG.2005.854929 | |||||
出版者 | ||||||
出版者 | Institute of Electrical and Electronics Engineers IEEE | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Many applications of the single-axis controlled repulsive-type magnetic bearing have been proposed earlier. However, both passive and active magnetic bearings are employed in most of such systems. In this paper, a new permanent magnet (PM) repulsive-type micromass measurement system is developed. The repulsive forces of the PM section are used effectively to keep the radial direction stable where the electromagnets, control circuits, and peripheral devices needed for controlling the unstable direction are simplified. The configuration, control design, and operating characteristics of the proposed system have been presented. | |||||