Comparison of regional myocardial Technetium-99m-MIBI uptake between ECG-gated and ungated SPECT imaging
http://hdl.handle.net/2297/7451
http://hdl.handle.net/2297/7451d56a2342-fab7-4781-87e2-8f443244ace3
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-ONOGUHI-M-181.pdf (1.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Comparison of regional myocardial Technetium-99m-MIBI uptake between ECG-gated and ungated SPECT imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Onoguchi, Masahisa
× Onoguchi, Masahisa× Maruno, Hirotaka× Fujinaga, Tsuyoshi× Komiyama, Nobuyuki× Takayama, Teruhiko× Murata, Hajime |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学大学院医学系研究科量子医療技術学 | |||||
書誌情報 |
Journal of Nuclear Medicine Technology 巻 25, 号 3, p. 181-186, 発行日 1997-09-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0091-4916 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00703709 | |||||
出版者 | ||||||
出版者 | Society of Nuclear Medicine | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Technetium-99m-MlBI uptake was compared between ECG-gated and ungated SPECT images in 10 normal subjects and 10 patients with coronary artery disease to investigate the effects of wall motion on regional myocardial uptake. Methods: Left ventricular ejection fraction (LVEF) and wall motion were evaluated using the first-pass data acquired immediately after injection of 1110 MBq 99mTc-MIBI. A transaxial ungated image was reconstructed with cumulative data during a cardiac cycle. For transaxial gated images, data during a cardiac cycle were divided into eight frames and the first seven frames were used. The lateral/septal ratios for ungated and gated images were obtained using the counts in the ROIs drawn in the lateral and the septal walls. Results: In 10 normal subjects, the lateral/septal ratio for gated increased during end-systole. The mean of the lateral/septal ratio was significantly lower for ungated than for gated (1.025 vs. 1.077, p < 0.05). In patients with septal wall asynergy and a normokinetic lateral wall, the mean of the lateral/septal ratios was significantly lower for ungated than for gated (1.267 vs. 1.325, p < 0.01). Conclusion: Ungated SPECT acquisition may underestimate regional myocardial uptake when myocardial wall motion is good, therefore, ECG-gated data should be acquired for accurate assessment of regional myocardial uptake of 99mTc-MIBI. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |