ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. A. 人間社会研究域; 人文学類・法学類・経済学類・学校教育学類・地域創造学類・国際学類
  2. a 10. 学術雑誌掲載論文
  3. 1-5.査読済論文(学校教育系)

Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies

http://hdl.handle.net/2297/12257
http://hdl.handle.net/2297/12257
5b3b555b-a626-416f-8157-7b9e85175fd1
名前 / ファイル ライセンス アクション
ED-PR-DEMURA-S-161.pdf ED-PR-DEMURA-S-161.pdf (942.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-02
タイトル
タイトル Relationships between Force-Time Parameters and Muscle Oxygenation Kinetics during Maximal Sustained Isometric Grip and Maximal Repeated Rhythmic Grip with Different Contraction Frequencies
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Demura, Shinichi

× Demura, Shinichi

WEKO 168
e-Rad 20155485
研究者番号 20155485

Demura, Shinichi

Search repository
Nakada, Masakatsu

× Nakada, Masakatsu

WEKO 4282

Nakada, Masakatsu

Search repository
Yamaji, Shunsuke

× Yamaji, Shunsuke

WEKO 4283

Yamaji, Shunsuke

Search repository
Nagasawa, Yoshinori

× Nagasawa, Yoshinori

WEKO 4284

Nagasawa, Yoshinori

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学人間社会研究域人間科学系
書誌情報 Journal of physiological anthropology

巻 27, 号 3, p. 161-168, 発行日 2008-05-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1345-3475
NCID
収録物識別子タイプ NCID
収録物識別子 AA12113950
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.2114/jpa2.27.161
出版者
出版者 日本生理人類学会
抄録
内容記述タイプ Abstract
内容記述 The purposes of this study were to examine the relationships between various force-time parameters and muscle oxygenation kinetics during maximal sustained isometric grip (SIG) and maximal repeated rhythmic grips (RRG) with different grip intervals (interval times: 5, 4, 3, and 2 s). Subjects were 10 healthy young males, aged 20-26 years (height 173.9±7.3 cm, body mass 71.5±11.2 kg). After measuring maximal grip force, each subject performed the SIG and RRG tests with a target frequency of 12, 15, 20, and 30 grips・min^<-1> (interval times: 5, 4, 3, and 2 s, respectively) for 6 min. The decreasing time until 80% MVC showed significant and high correlations with final force values in RRGs with over 3 s intervals (r=0.866-0.941), but not in the SIG and RRG with a 2 s interval. The time at the lowest Oxy-Hb/Mb value showed a significant and high correlation with the time at the highest Deoxy-Hb/Mb value only in the SIG and RRG with a 2 s interval (r=0.825-0.916). Oxy-Hb/Mb decreases markedly and deoxy-Hb/Mb increases after the onset of SIG due to the obstruction of blood flow caused by the increase in intramuscular pressure. A similar physiological response to that of SIG occurs also in RRG with a 2 s interval, but RRGs with intervals over 3 s achieve more resumption of blood flow in the muscular relaxation phase. Hence, in spite of the same RRGs, it was determined that RRGs with intervals over 3 s differ significantly in a changing pattern of grip force and muscle oxygen kinetics from RRGs with a 2 s interval.
権利
権利情報 日本生理人類学会;本文データは日本生理人類学会の許諾に基づきCiNiiから複製したものである
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views