ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(理)

Preconcentration and Determination of Traces of Cobalt(II) as a Thenoyltrifluoroacetone Complex with Dibenzo-24-Crown-8 by Synergistic Extraction and Graphite Furnace Atomic Absorption Spectrophotometry

http://hdl.handle.net/2297/35242
http://hdl.handle.net/2297/35242
f92aba03-b21d-475c-887d-930062e19552
名前 / ファイル ライセンス アクション
SC-PR-HONJO-T-63-73.pdf SC-PR-HONJO-T-63-73.pdf (743.7 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Preconcentration and Determination of Traces of Cobalt(II) as a Thenoyltrifluoroacetone Complex with Dibenzo-24-Crown-8 by Synergistic Extraction and Graphite Furnace Atomic Absorption Spectrophotometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Camagong, Cristina T.

× Camagong, Cristina T.

WEKO 16185

Camagong, Cristina T.

Search repository
Hossain, Kazi Zakir

× Hossain, Kazi Zakir

WEKO 16186

Hossain, Kazi Zakir

Search repository
Honjo, Takaharu

× Honjo, Takaharu

WEKO 15598
e-Rad 90019498
研究者番号 90019498

Honjo, Takaharu

Search repository
書誌情報 Solvent Extraction Research and Development, Japan

巻 8, p. 63-73, 発行日 2001-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1341-7215
NCID
収録物識別子タイプ NCID
収録物識別子 AA11114608
出版者
出版者 Japan Association of Solvent Extraction 日本溶媒抽出学会
抄録
内容記述タイプ Abstract
内容記述 A new solvent extraction technique for the enrichment and determination of traces of cobalt (II) in natural waters was developed by means of the synergistic action of thenoyltrifluoroacetone (TTA) and dibenzo-24-crown-8 (DB24C8) in o-dichlorobenzene combined with graphite furnace atomic absorption spectrophotometry. The composition of the resulting adduct was determined by slope analysis revealing a stoichiometric formula of Co(TTA)2DB24C8 with a stability constant (log β) of 5.51. Calibration plots of cobalt (II) gave linear responses (r2 = 0.999) with increasing concentration of the standards in the ng/mL range. The detection limit was 0.015 ng/mL. The analytical precision was less than 4% (RSD), and the spike recoveries of cobalt (II) was ≥ 89% for the preconcentration factors up to 20-fold. The method was applied to the determination of the cobalt content in Kakehashi river (Komatsu City), Japan Sea (Uchinada Town) and tap water (Kanazawa University) samples and the results were found to be 5.82±0.73 ng/mL, 0.097±0.010 and < 0.015 ng/mL, respectively.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 09:48:25.895689
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3