WEKO3
インデックスリンク
アイテム
Grafting of phenylboronic acid on a glassy carbon electrode and its application as a reagentless glucose sensor
http://hdl.handle.net/2297/26282
http://hdl.handle.net/2297/26282e71f30ee-c57e-456f-997d-6255097f933b
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-10-03 | |||||
| タイトル | ||||||
| タイトル | Grafting of phenylboronic acid on a glassy carbon electrode and its application as a reagentless glucose sensor | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Morita, Kotaro
× Morita, Kotaro× Hirayama, Naoki× Imura, Hisanori× Yamaguchi, Akira× Teramae, Norio |
|||||
| 提供者所属 | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | 金沢大学理工研究域物質化学系 | |||||
| 書誌情報 |
Journal of Electroanalytical Chemistry 巻 656, 号 1-2, p. 192-197, 発行日 2011-06-15 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 1572-6657 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA10836527 | |||||
| DOI | ||||||
| 関連タイプ | isVersionOf | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.jelechem.2010.11.023 | |||||
| 出版者 | ||||||
| 出版者 | Elsevier BV | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Phenylboronic acid (PBA) was covalently grafted to the surface of glassy carbon (GC) electrodes using electrochemical reduction of in situ generated diazonium cation. The grafting of GC surfaces was controlled by varying both the concentration of precursor 3-aminophenylboronic acid and the number of potential cycling during the grafting procedure. Cyclic voltammetry (CV) and eletrochemical impedance spectroscopy (EIS) were used to confirm the grafting of the PBA group to the GC surface and formation of multilayer. The barrier properties of the grafted GC electrodes were studied in the presence of a redox probe such as Fe (CN)63 - / 4 - by CV. Additionally, the resultant PBA multilayer on the GC electrode was applied for glucose detection utilizing the EIS technique in the presence of a redox probe molecule. Then, the complexation ability of the grafted layers with glucose was also confirmed as an increase of total impedance at non-faradic EIS measurement. © 2010 Elsevier B.V. All rights reserved. | |||||