WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "170e83a3-e89e-4dc4-bc30-e09991f01e9a"}, "_deposit": {"created_by": 3, "id": "11778", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "11778"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00011778", "sets": ["1033"]}, "author_link": ["1113", "112490", "8051", "18470", "18322", "18323"], "item_7_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1974-03-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "134", "bibliographicPageStart": "125", "bibliographicVolumeNumber": "8", "bibliographic_titles": [{"bibliographic_title": "金沢大学工学部紀要 = Memoirs of the Faculty of Technology Kanazawa University"}]}]}, "item_7_creator_34": {"attribute_name": "著者別表示", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Matsuura, Kohki"}], "nameIdentifiers": [{"nameIdentifier": "18322", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40019740", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40019740"}]}, {"creatorNames": [{"creatorName": "Tsuda, Nobuo"}], "nameIdentifiers": [{"nameIdentifier": "112490", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Gaishi"}], "nameIdentifiers": [{"nameIdentifier": "18323", "nameIdentifierScheme": "WEKO"}]}]}, "item_7_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": " Theoretical and experimental evaluation of extremely low level photodetection techniques is described. The techniques evaluated are DC method and Single Photoelectron Counting method both using photomultiplier tubes. The photomultiplier tubes used are HTV-R132(S10) and HTV-R376(S20). Optimum values of applied voltage and threshold level of the multiplier tubes obtained by experiments are shown. The best signal sensitivity of 4.5 photo-electrons per second for a counting time of 10 seconds is acquired for HTV-R376 which is cooled down to -30 °C. This means the light power of 2.8x 10⁻¹⁷ w (6328 Å) can be detected by the observation of 10 seconds. ", "subitem_description_type": "Abstract"}]}, "item_7_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.24517/00011765", "subitem_identifier_reg_type": "JaLC"}]}, "item_7_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "金沢大学工学部 = Faculty of Technology Kanazawa University"}]}, "item_7_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00044309", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0022-832X", "subitem_source_identifier_type": "ISSN"}]}, "item_7_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "松浦, 弘毅"}], "nameIdentifiers": [{"nameIdentifier": "1113", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40019740", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040019740"}]}, {"creatorNames": [{"creatorName": "津田, 伸正"}], "nameIdentifiers": [{"nameIdentifier": "18470", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 外史"}], "nameIdentifiers": [{"nameIdentifier": "8051", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AN00044309-8-1-125.pdf", "filesize": [{"value": "265.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 265100.0, "url": {"label": "AN00044309-8-1-125.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/11778/files/AN00044309-8-1-125.pdf"}, "version_id": "f3cccbaf-aedf-4615-9ef4-6117ba4ddf20"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "極微弱光の検出", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "極微弱光の検出"}, {"subitem_title": "Detection of Weak Light Signals", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "3", "path": ["1033"], "permalink_uri": "https://doi.org/10.24517/00011765", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "11778", "relation": {}, "relation_version_is_last": true, "title": ["極微弱光の検出"], "weko_shared_id": 3}
極微弱光の検出
https://doi.org/10.24517/00011765
https://doi.org/10.24517/0001176514da5816-0404-4390-929f-ad5fe10e13f2
名前 / ファイル | ライセンス | アクション |
---|---|---|
AN00044309-8-1-125.pdf (265.1 kB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | 極微弱光の検出 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Detection of Weak Light Signals | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.24517/00011765 | |||||
ID登録タイプ | JaLC | |||||
著者 |
松浦, 弘毅
× 松浦, 弘毅× 津田, 伸正× 山本, 外史 |
|||||
著者別表示 |
Matsuura, Kohki
× Matsuura, Kohki× Tsuda, Nobuo× Yamamoto, Gaishi |
|||||
書誌情報 |
金沢大学工学部紀要 = Memoirs of the Faculty of Technology Kanazawa University 巻 8, 号 1, p. 125-134, 発行日 1974-03-25 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0022-832X | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00044309 | |||||
出版者 | ||||||
出版者 | 金沢大学工学部 = Faculty of Technology Kanazawa University | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Theoretical and experimental evaluation of extremely low level photodetection techniques is described. The techniques evaluated are DC method and Single Photoelectron Counting method both using photomultiplier tubes. The photomultiplier tubes used are HTV-R132(S10) and HTV-R376(S20). Optimum values of applied voltage and threshold level of the multiplier tubes obtained by experiments are shown. The best signal sensitivity of 4.5 photo-electrons per second for a counting time of 10 seconds is acquired for HTV-R376 which is cooled down to -30 °C. This means the light power of 2.8x 10⁻¹⁷ w (6328 Å) can be detected by the observation of 10 seconds. | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |