  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 40. 学会・会議等発表資料
  3. Recent development in computational science
  4. Vol. 2

Self -Siphon Simulation Using Molecular Dynamics Method

http://hdl.handle.net/2297/44057
http://hdl.handle.net/2297/44057
e46ad286-9c43-43e6-aeef-260dd07c1cef
名前 / ファイル ライセンス アクション
ISCS2011Proceedings-9-16.pdf ISCS2011Proceedings-9-16.pdf (920.8 kB)
Item type 報告書 / Research Paper(1)
公開日 2017-10-03
タイトル
タイトル Self -Siphon Simulation Using Molecular Dynamics Method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_18ws
資源タイプ research report
著者 Sparisoma, Viridi

× Sparisoma, Viridi

WEKO 18875

Sparisoma, Viridi

Search repository
Suprijadi

× Suprijadi

WEKO 18876

Suprijadi

Search repository
Siti, Nurul Khotimah

× Siti, Nurul Khotimah

WEKO 18877

Siti, Nurul Khotimah

Search repository
Novitrian

× Novitrian

WEKO 18878

Novitrian

Search repository
Fannia, Masterika

× Fannia, Masterika

WEKO 18879

Fannia, Masterika

Search repository
書誌情報 Recent development in computational science : Selected Papers from the International Symposium on Computational Science - International Symposium on Computational Science Kanazawa University, Japan

巻 2, p. 9-16, 発行日 2011-10-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 2223-0785
出版者
出版者 Kanazawa e-Publishing
抄録
内容記述タイプ Abstract
内容記述 A self activated siphon, which is also known as self siphon or self priming siphon, is simulated using molecular dynamics (MD) method in order to study its behavior, especially why it has a critical height that prevents fluid from flowing through it. The trajectory of the fluid interface with air in front of the flow or the head is also fitted the trajectory modeled by parametric equations, which is derived from geometry construction of the self siphon. Numerical equations solved using MD method is derived from equations of motion of the head which is obtained by introducing all considered forces influencing the movement of it. Time duration needed for fluid to pass the entire tube of the self siphon, τ, obtained from the simulation is compared quantitatively to the observation data from the previous work and it shows inverse behavior. Length of the three vertical segments are varied independently using a parameter for each segment, which are N5, N3, and N1. Room parameters of N5, N3, and N1 are constructed and the dependency of τ to these parameters are discussed.
権利
権利情報 Organizing Committee of ISCS
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:28:38.076102
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3