ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

New functional polar maps for estimating regional cardiac function using ECG-gated technetium-99m-tetrofosmin SPECT

http://hdl.handle.net/2297/6999
http://hdl.handle.net/2297/6999
bf289b29-ec02-4f58-8983-a854253d95ef
名前 / ファイル ライセンス アクション
ME-PR-ONOGUCHI-M-29.pdf ME-PR-ONOGUCHI-M-29.pdf (393.4 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル New functional polar maps for estimating regional cardiac function using ECG-gated technetium-99m-tetrofosmin SPECT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Onoguchi, Masahisa

× Onoguchi, Masahisa

WEKO 352
金沢大学研究者情報 30283120
研究者番号 30283120

Onoguchi, Masahisa

Search repository
Maruno, Hirotaka

× Maruno, Hirotaka

WEKO 20051

Maruno, Hirotaka

Search repository
Takayama, Teruhiko

× Takayama, Teruhiko

WEKO 20052
e-Rad 20171556
研究者番号 20171556

Takayama, Teruhiko

Search repository
Naoi, Yutaka

× Naoi, Yutaka

WEKO 20053

Naoi, Yutaka

Search repository
Irimoto, Masahiro

× Irimoto, Masahiro

WEKO 20054

Irimoto, Masahiro

Search repository
Maehara, Nobuyuki

× Maehara, Nobuyuki

WEKO 20055

Maehara, Nobuyuki

Search repository
Katayama, Hitoshi

× Katayama, Hitoshi

WEKO 20056

Katayama, Hitoshi

Search repository
Murata, Hajime

× Murata, Hajime

WEKO 20057

Murata, Hajime

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科量子医療技術学
書誌情報 Journal of Nuclear Medicine Technology

巻 28, 号 1, p. 29-35, 発行日 2000-03-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0091-4916
出版者
出版者 Society of Nuclear Medicine
抄録
内容記述タイプ Abstract
内容記述 Objective: The purpose of this work was to develop functional parameters to analyze regional cardiac function using ECG-gated 99mTc-tetrofosmin SPECT. Our goal was to develop a methodology that used slice thickness correction, the generation of a time-activity curve and a polar map. Methods: Fourteen normal patients without evidence of coronary artery disease were studied. One hour after intravenous injection of 740-1110 MBq (20-30 mCi) 99mTc-tetrofosmin, ECG-gated SPECT data were acquired by dividing a cardiac cycle into 12 frames. The SPECT data were reconstructed from 11 of 12 frames into 3 views. The reconstruction of these images was repeated after performing slice thickness correction. Excluding the effect of different apex-to-base lengths at any frame during a cardiac cycle, 10 short-axis images with the same slice thickness were obtained. Each short-axis image was divided by 40 radii into 40 segments. The time-activity curve was generated from the total counts included in each segment plus both neighboring segments. Subsequently the curve fitting was performed using the second Fourier function. Results: From fitted curves and their differentials, we calculated end-systolic count, end-diastolic count, percent count increase, uptake, peak contraction rate, peak distention rate and contraction time. Conclusion: The functional polar maps visually demonstrated regional myocardial function. This method is expected to be helpful for assessing regional cardiac function using 99mTc-tetrofosmin.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 http://tech.snmjournals.org/cgi/content/short/28/1/29
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 09:48:17.325080
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3