Diagnostic usefulness of the post-exercise systolic blood pressure response for the detection of coronary artery disease in patients with diabetes mellitus

http://hdl.handle.net/2297/7531
http://hdl.handle.net/2297/7531
d5d71565-94a6-46ee-85e1-54c786aa621d
名前 / ファイル ライセンス アクション
ME-PR-MABUCHI-H-949.pdf ME-PR-MABUCHI-H-949.pdf (316.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Diagnostic usefulness of the post-exercise systolic blood pressure response for the detection of coronary artery disease in patients with diabetes mellitus
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yamaguchi, Masato

× Yamaguchi, Masato

WEKO 20099
e-Rad 90313650
研究者番号 90313650

Yamaguchi, Masato

Search repository
Shimizu, Masami

× Shimizu, Masami

WEKO 20345

Shimizu, Masami

Search repository
Ino, Hidekazu

× Ino, Hidekazu

WEKO 20204
研究者番号 20272966

Ino, Hidekazu

Search repository
Okeie, Kazuyasu

× Okeie, Kazuyasu

WEKO 20346

Okeie, Kazuyasu

Search repository
Yasuda, Toshihiko

× Yasuda, Toshihiko

WEKO 20347

Yasuda, Toshihiko

Search repository
Fujino, Noboru

× Fujino, Noboru

WEKO 273
e-Rad 40361993
金沢大学研究者情報 40361993
研究者番号 40361993

Fujino, Noboru

Search repository
Fujii, Hiroyuki

× Fujii, Hiroyuki

WEKO 20348

Fujii, Hiroyuki

Search repository
Mabuchi, Tomohito

× Mabuchi, Tomohito

WEKO 20349

Mabuchi, Tomohito

Search repository
Mabuchi, Hiroshi

× Mabuchi, Hiroshi

WEKO 389
e-Rad 00019960
研究者番号 00019960

Mabuchi, Hiroshi

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科
書誌情報 Japanese Circulation Journal

巻 64, 号 12, p. 949-952, 発行日 2000-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0047-1828
NCID
収録物識別子タイプ NCID
収録物識別子 AA00690731
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1253/jcj.64.949
出版者
出版者 日本循環器学会
抄録
内容記述タイプ Abstract
内容記述 Patients with diabetes mellitus (DM) often have a positive result on exercise testing despite a normal coronary arteriogram, which indicates that exercise-induced ST depression is not always an accurate indicator of the presence of coronary artery disease (CAD) in such patients. The present study evaluated the usefulness of the post-exercise systolic blood pressure (SBP) response for the detection of CAD in 47 consecutive patients with DM. Significant stenotic lesions were detected by angiography in 25 patients; 18 of these had true positive (TP) exercise testing results, and 7 had false negative (FN) results. No significant stenotic lesions were detected in the remaining 22 patients and of these 10 had true negative (TN) exercise testing results, and 12 had false positive (FP) results. The SBP ratio (SBP after 3 min of recovery divided by the SBP at peak exercise) was significantly higher in patients with coronary stenoses than in those without. Analysis of the relative cumulative frequency revealed that a SBP ratio greater than 0.87 was associated with significant stenoses. The sensitivity, specificity, and accuracy of ST change combined with a SBP ratio greater than 0.87 for detecting stenoses in patients with DM were 68%, 82%, and 74%, respectively. These results suggest that calculating the SBP ratio, in combination with monitoring for ST depression, improves the accuracy of treadmill exercise testing for the detection of CAD in patients with DM.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
関連URI
識別子タイプ URI
関連識別子 http://www.jstage.jst.go.jp/article/jcj/64/12/64_949/_article/-char/en
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:11:38.841644
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3