ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Real-time monitoring of respiration rhythm and pulse rate during sleep

http://hdl.handle.net/2297/6690
http://hdl.handle.net/2297/6690
95c6dcab-a901-4427-94dd-40703cc6702a
名前 / ファイル ライセンス アクション
ME-PR-NEMOTO-T-2533.pdf ME-PR-NEMOTO-T-2533.pdf (2.4 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Real-time monitoring of respiration rhythm and pulse rate during sleep
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Zhu, Xin

× Zhu, Xin

WEKO 20683

Zhu, Xin

Search repository
Chen, Wenxi

× Chen, Wenxi

WEKO 20684

Chen, Wenxi

Search repository
Nemoto, Tetsu

× Nemoto, Tetsu

WEKO 577
e-Rad 90126243
研究者番号 90126243

Nemoto, Tetsu

Search repository
Kanemitsu, Yumi

× Kanemitsu, Yumi

WEKO 20685

Kanemitsu, Yumi

Search repository
Kitamura, Keiichiro

× Kitamura, Keiichiro

WEKO 324
e-Rad 80283117
金沢大学研究者情報 80283117
研究者番号 80283117

Kitamura, Keiichiro

Search repository
Yamakoshi, Kenichi

× Yamakoshi, Kenichi

WEKO 42
e-Rad 40014310
研究者番号 40014310

Yamakoshi, Kenichi

Search repository
Wei, Daming

× Wei, Daming

WEKO 20686

Wei, Daming

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科先端医療技術学
書誌情報 IEEE Transactions on Biomedical Engineering

巻 53, 号 12, p. 2553-2563, 発行日 2006-01-01
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1109/tbme.2006.884641
出版者
出版者 IEEE
抄録
内容記述タイプ Abstract
内容記述 A noninvasive and unconstrained real-time method to detect the respiration rhythm and pulse rate during sleep is presented. By employing the à trous algorithm of the wavelet transformation (WT), the respiration rhythm and pulse rate can be monitored in real-time from a pressure signal acquired with a pressure sensor placed under a pillow. The waveform for respiration rhythm detection is derived from the 26 scale approximation, while that for pulse rate detection is synthesized by combining the 24 and 2 5 scale details. To minimize the latency in data processing and realize the highest real-time performance, the respiration rhythm and pulse rate are estimated by using waveforms directly derived from the WT approximation and detail components without the reconstruction procedure. This method is evaluated with data collected from 13 healthy subjects. By comparing with detections from finger photoelectric plethysmograms used for pulse rate detection, the sensitivity and positive predictivity were 99.17% and 98.53%, respectively. Similarly, for respiration rhythm, compared with detections from nasal thermistor signals, results were 95.63% and 95.42%, respectively. This study suggests that the proposed method is promising to be used in a respiration rhythm and pulse rate monitor for real-time monitoring of sleep-related diseases during sleep. © 2006 IEEE.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
シリーズ
関連名称 19
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 12:02:46.304275
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3