A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images

http://hdl.handle.net/2297/2859
http://hdl.handle.net/2297/2859
73c10049-c6d3-476e-957f-e9f3c4e481f9
名前 / ファイル ライセンス アクション
ME-PR-TAKEMURA-T-01.pdf ME-PR-TAKEMURA-T-01.pdf (372.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル A rule-based scheme for detection of accessory cardiac bronchus in chest computed tomography images
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Takemura, Akihiro

× Takemura, Akihiro

WEKO 529
e-Rad 70313674
金沢大学研究者情報 70313674
研究者番号 70313674

Takemura, Akihiro

Search repository
Suzuki, M.

× Suzuki, M.

WEKO 20730

Suzuki, M.

Search repository
Harauchi, H.

× Harauchi, H.

WEKO 20731

Harauchi, H.

Search repository
Okumura, Y.

× Okumura, Y.

WEKO 20732

Okumura, Y.

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科
書誌情報 Computer-Assisted Radiology and Surgery

巻 1, 号 SUPPL.7, p. 362-364, 発行日 2006-06-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1861-6410
出版者
出版者 Springer Verlag
抄録
内容記述タイプ Abstract
内容記述 Accessory cardiac bronchus (ACB) is a rare bronchial anomaly This anomaly often goes undetected due to its low frequency and lack of symptoms in most cases. However, ACB should be diagnosed because it sometimes causes infection and/or hemoptysis. Here, we present a rule-based and 2D-based scheme, which can detect ACB in chest multi-slice computed tomography volume data. We have developed a computer-aided scheme for detection of ACB. This scheme performs extraction of the bronchial tree structure, determination of trachea bifurcation, and detection of ACB on the right bronchi. The sensitivity and specificity of this scheme were evaluated in 9 cases: 3 with ACB. 3 with tracheal bronchus and no ACB, and 3 normal cases. All of the subjects were examined with MSCT scanners (LightSpeed Ultra 16 and LightSpeed Plus; GE Medical Systems, Milwaukee. WI, USA) using a contiguous slice thickness of 2.5 mm. We also measured the time taken for examination using the scheme on a personal computer (CPU: 2.4 GHz Pentium 4, Memory: 1 Gbyte; OS: Red Hat Linux 9). The scheme detected ACB in two of the three cases (Sensitivity: 66.7%), and all of the cases without ACB were identified as having no ACB (Specificity: 100%). The mean processing time was 13.5 seconds (SD: 6.4) per case, and therefore this scheme could be suitable for prechecking before actual diagnosis.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 09:32:32.648019
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3