A computer-aided temporal and dynamic subtraction technique of the liver for detection of small hepatocellular carcinomas on abdominal CT images

http://hdl.handle.net/2297/2927
http://hdl.handle.net/2297/2927
c32670cc-21d2-49f6-80fc-439e662cc620
名前 / ファイル ライセンス アクション
ME-PR-OKUMURA-E-01.pdf ME-PR-OKUMURA-E-01.pdf (489.4 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル A computer-aided temporal and dynamic subtraction technique of the liver for detection of small hepatocellular carcinomas on abdominal CT images
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Okumura, Eiichiro

× Okumura, Eiichiro

WEKO 20739

Okumura, Eiichiro

Search repository
Sanada, Shigeru

× Sanada, Shigeru

WEKO 13121
e-Rad 50020029
研究者番号 50020029

Sanada, Shigeru

Search repository
Suzuki, Masayuki

× Suzuki, Masayuki

WEKO 20740

Suzuki, Masayuki

Search repository
Matsui, A.

× Matsui, A.

WEKO 20741

Matsui, A.

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科量子医療技術学
書誌情報 Physics in Medicine and Biology

巻 51, 号 19, p. 4759-4771, 発行日 2006-10-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/0031-9155/51/19/003
その他の識別子
内容記述タイプ Other
内容記述 003
出版者
出版者 Institute of Physics
抄録
内容記述タイプ Abstract
内容記述 It is often difficult for radiologists to identify small hepatocellular carcinomas (HCCs) due to insufficient contrast enhancement. Therefore, we have developed a new computer-aided temporal and dynamic subtraction technique to enhance small HCCs, after automatically selecting images set at the same anatomical position from the present (non-enhanced and arterial-phase CT images) and previous images. The present study was performed with CT images from 14 subjects. First, we used template-matching based on similarities in liver shape between the present (non-enhanced and arterial-phase CT images) and previous arterial-phase CT images at the same position. Temporal subtraction images were then obtained by subtraction of the previous image from the present image taken at the same position of the liver. Dynamic subtraction images were also obtained by subtraction of non-enhanced CT images from arterial-phase CT images taken at the same position of the liver. Twenty-one of 22 nodules (95.5%) with contrast enhancement were visualized in temporal and dynamic subtraction images. Compared with present arterial-phase CT images, increases of 150% and 140% in nodule-to-liver contrast were observed on dynamic and temporal subtraction images, respectively. These subtraction images may be useful as reference images in the detection of small moderately differentiated HCCs. © 2006 IOP Publishing Ltd.
権利
権利情報 Copyright © (2006)Institute of Physics
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 11:15:31.322541
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3