ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Usefulness of medium-Energy Collimator for Sentinel Node Lymphoscintigraphy Imaging in Breast Cancer Patients

http://hdl.handle.net/2297/2787
http://hdl.handle.net/2297/2787
e2eab4a1-a83c-44e4-805c-61724ee86e77
名前 / ファイル ライセンス アクション
ME-PR-TAKYAMA-H-153.pdf ME-PR-TAKYAMA-H-153.pdf (198.1 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Usefulness of medium-Energy Collimator for Sentinel Node Lymphoscintigraphy Imaging in Breast Cancer Patients
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Tsushima, Hiroyuki

× Tsushima, Hiroyuki

WEKO 21125

Tsushima, Hiroyuki

Search repository
Takayama, Teruhiko

× Takayama, Teruhiko

WEKO 20052
e-Rad 20171556
研究者番号 20171556

Takayama, Teruhiko

Search repository
Yamanaga, Takashi

× Yamanaga, Takashi

WEKO 21126

Yamanaga, Takashi

Search repository
Kizu, Hiroto

× Kizu, Hiroto

WEKO 21127

Kizu, Hiroto

Search repository
Shimonishi, Yoshihiro

× Shimonishi, Yoshihiro

WEKO 21128

Shimonishi, Yoshihiro

Search repository
Kosakai, Kazuhisa

× Kosakai, Kazuhisa

WEKO 21129

Kosakai, Kazuhisa

Search repository
Noguchi, Atsushi

× Noguchi, Atsushi

WEKO 21130

Noguchi, Atsushi

Search repository
Onoguchi, Masahisa

× Onoguchi, Masahisa

WEKO 21131

Onoguchi, Masahisa

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学大学院医学系研究科
提供者所属
内容記述タイプ Other
内容記述 小野口, 昌久
書誌情報 Journal of nuclear medicine technology

巻 34, 号 3, p. 153-159, 発行日 2006-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0091-4916
出版者
出版者 Society of Nuclear Medicine
抄録
内容記述タイプ Abstract
内容記述 This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. Methods: We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between a low-energy high-resolution (LEHR) collimator and a general-purpose ME collimator, and between energy windows centered at 141 keV and at 146 keV. Profile curves and image contrast were evaluated along with the visual interpretation of images. The most suitable imaging time was selected from the relationship between contrast and the data acquisition time. Results: The images obtained with the general-purpose ME collimator and the energy window centered at 141 keV were of poorer quality than those obtained with the LEHR collimator and the same energy window. However, the quality of the images obtained with the general-purpose ME collimator improved when the energy window was centered at 146 keV. The method involving the general-purpose ME collimator and the energy window centered at 146 keV showed excellent image quality similar to that obtained with the LEHR collimator. The enhancement of contrast was confirmed at more than 3 cm away from the center of the injection site. Stable contrast was obtained with a data acquisition time of 5 min, with the general-purpose ME collimator, and with the energy window centered at 146 keV. Conclusion: The method involving the general-purpose ME collimator and the energy window centered at 146 keV has the merit of the lymph node not being concealed by a lead shield. This new method is expected to improve the rate of detection of SLN and has the potential for shortening the acquisition time.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 09:47:47.254939
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3