ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Imaging parameter effects in apparent diffusion coefficient determination of magnetic resonance imaging

http://hdl.handle.net/2297/19223
http://hdl.handle.net/2297/19223
ce333468-4990-4353-a55c-cda375d68a7c
名前 / ファイル ライセンス アクション
ME-PR-OGURA-A-162.pdf ME-PR-OGURA-A-162.pdf (871.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Imaging parameter effects in apparent diffusion coefficient determination of magnetic resonance imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ogura, Akio

× Ogura, Akio

WEKO 21475

Ogura, Akio

Search repository
Hayakawa, Katsumi

× Hayakawa, Katsumi

WEKO 21476

Hayakawa, Katsumi

Search repository
Miyati, Tosiaki

× Miyati, Tosiaki

WEKO 120
e-Rad 80324086
金沢大学研究者情報 80324086
研究者番号 80324086

Miyati, Tosiaki

Search repository
Maeda, Fumie

× Maeda, Fumie

WEKO 21477

Maeda, Fumie

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学医薬保健研究域保健学系
提供者所属
内容記述タイプ Other
内容記述 京都市立病院
書誌情報 European Journal of Radiology

巻 76, 号 2, p. 162-166, 発行日 2010-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0720-048X
NCID
収録物識別子タイプ NCID
収録物識別子 AA10619405
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.ejrad.2009.06.031
出版者
出版者 Elsevier
抄録
内容記述タイプ Abstract
内容記述 Purpose: Although an apparent diffusion coefficient (ADC) value is often used for differential diagnosis of tumours, it varies with scanning parameters. The present study was performed to investigate the influence of imaging parameters, i.e., b value, repetition time (TR) and echo time (TE), on ADC value. Methods: The phantoms were scanned using diffusion weighted imaging (DWI) with changing b values (b = 0-3000 s/mm2), TR and TE to determine the influence on ADC. Moreover, ADC of the brain in normal volunteers was determined with varying b values (b = 0-1000 s/mm2). Results: Diffusion decay curves were obtained by biexponential fitting in all phantoms. The points where fast and slow components of the biexponential decay crossed were called turning points. The b values of turning points that crossed from the biexponential curve were different in each phantom. The b values of turning points depended on ADC of fast diffusion component. When ADC is calculated using two b values of front and back for the turning point, the ADC value may be different. Therefore, it was necessary to perform calculations by b value until the turning point to obtain the ADC value of the fast component. In addition, b ≥ 100 was recommended to avoid the influence of perfusion by blood. Furthermore, the choice of long TR and short TE was effective for accurate measurement of ADC. Conclusion: It is important to determine the turning point for measuring ADC. © 2009 Elsevier Ireland Ltd. All rights reserved.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views