WEKO3
インデックスリンク
アイテム
Bulk motion-independent analyses of water diffusion changes in the brain during the cardiac cycle
http://hdl.handle.net/2297/19320
http://hdl.handle.net/2297/19320ca368833-1476-4062-81f6-1bde9c4eebb6
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Bulk motion-independent analyses of water diffusion changes in the brain during the cardiac cycle | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Nakamura, Tomoya
× Nakamura, Tomoya× Miyati, Tosiaki× Kasai, Harumasa× Ohno, Naoki× Yamada, Masato× Mase, Mitsuhito× Hara, Masaki× Shibamoto, Yuta× Suzuki, Yuriko× Ichikawa, Katsuhiro |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
Radiological Physics and Technology 巻 2, 号 2, p. 133-137, 発行日 2009-07-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12236881 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-009-0056-3 | |||||
出版者 | ||||||
出版者 | 日本放射線技術学会&医学物理学会 = Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated dynamic changes in water diffusion in the brain during the cardiac cycle by using cine diffusion MRI. On a 1.5-T MRI, ECG-triggered single-shot diffusion echo planar imaging was used with sensitivity encoding, halfscan, and rectangular field of view techniques for minimizing bulk motion effects such as brain pulsation, with a data-sampling window of 3 ms. The apparent diffusion coefficient (ADC) and fractional anisotropy (FA) in the white matter zone were determined in ten healthy volunteers and then compared with the intracranial volume change (ICVC) revealed by phase-contrast cine MRI during the cardiac cycle. In addition, a frequency analysis of these waveforms was performed. ADC and FA values changed significantly during the cardiac cycle, despite minimizing the effect of bulk motion, i.e., independent of bulk motion. The ADC was synchronized with the ICVC during the cardiac cycle. A significant positive correlation was noted among their amplitudes. Analysis of the dynamic change of water diffusion by use of cine diffusion MRI facilitates the assessment of intracranial conditions. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |