WEKO3
インデックスリンク
アイテム
Maxillary stability after Le Fort I osteotomy with self-setting α-tricalcium phosphate and an absorbable plate
http://hdl.handle.net/2297/33413
http://hdl.handle.net/2297/33413cc3cbc02-95a7-4bc4-87d3-c6d105ff12f4
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-10-03 | |||||
| タイトル | ||||||
| タイトル | Maxillary stability after Le Fort I osteotomy with self-setting α-tricalcium phosphate and an absorbable plate | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Ueki, Koichiro
× Ueki, Koichiro× Okabe, Katsuhiko× Marukawa, Kohei× Mukozawa, Aya× Moroi, Akinori× Miyazaki, Mao× Sotobori, Megumi× Ishihara, Yuri× Yoshizawa, Kunio× Ooi, Kazuhiro× Kawashiri, Shuichi |
|||||
| 書誌情報 |
International Journal of Oral and Maxillofacial Surgery 巻 42, 号 5, p. 597-607, 発行日 2013-03-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0901-5027 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA10682150 | |||||
| DOI | ||||||
| 関連タイプ | isVersionOf | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.ijom.2012.10.026 | |||||
| 出版者 | ||||||
| 出版者 | Elsevier | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | The purpose of this study was to compare retrospectively postoperative differences in maxillary stability after Le Fort I osteotomy and fixation with an unsintered hydroxyapatite (u-HA)/poly-l-lactic acid (PLLA) plate with or without self-setting α-tricalcium phosphate (Biopex ®) as interpositional material. Subjects comprised 45 patients diagnosed with mandibular prognathism with maxillary retrognathism and mandibular prognathism with bimaxillary asymmetry. All patients underwent Le Fort I osteotomy and bilateral sagittal split ramus osteotomy with fixation by uHA/PLLA plates. Patients were divided into 4 groups consisting of 9 maxillary impaction cases with Biopex ® (group 1) to fill the gap between the bone segments, 14 maxillary advancement cases with Biopex ® (group 2), 8 maxillary impaction cases without Biopex ® (group 3) and 14 maxillary advancement cases without Biopex ® (group 4). Changes in cepahalometric parameters at time intervals (1, 3 and 12 months) between the groups were compared. Results showed that stability did not depend on the use or otherwise of Biopex ®. © 2012 International Association of Oral and Maxillofacial Surgeons. | |||||
| 著者版フラグ | ||||||
| 出版タイプ | AM | |||||
| 出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
| 関連URI | ||||||
| 識別子タイプ | URI | |||||