Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study
http://hdl.handle.net/2297/29562
http://hdl.handle.net/2297/29562b9179a4b-d62a-46ad-a291-718d4e612f4b
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2017-10-03 | |||||
| タイトル | ||||||
| タイトル | Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| 著者 |
Nakajima, Kenichi
× Nakajima, Kenichi× Okuda, Koichi× Matsuo, Shinro× Yoshita, Mitsuhiro× Taki, Junichi× Yamada, Masahito× Kinuya, Seigo |
|||||
| 書誌情報 |
European Journal of Nuclear Medicine and Molecular Imaging 巻 39, 号 1, p. 113-119, 発行日 2012-01-01 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 1619-7070 | |||||
| NCID | ||||||
| 収録物識別子タイプ | NCID | |||||
| 収録物識別子 | AA1161516X | |||||
| DOI | ||||||
| 関連タイプ | isVersionOf | |||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1007/s00259-011-1963-1 | |||||
| 出版者 | ||||||
| 出版者 | Springer-Verlag | |||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Purpose: This study was performed to demonstrate that the results obtained with a calibration phantom could be used as a tool for standardizing measurement of heart to mediastinum (H/M) ratio in cardiac metaiodobenzylguanidine (MIBG) imaging. Methods: Images of the phantom containing 123I-MIBG were acquired on the cameras in 10 hospitals (11 camera types) to determine the relationship between H/M ratios using different collimators: low-energy (LE) and medium-energy (ME)/low-medium-energy (LME) collimators. The effect of standardization on the ME-comparable H/M ratio was examined in two settings: a Japanese standard MIBG database (n = 62) and multicentre studies (n = 49). In a multicentre study, probable Alzheimer's disease (AD, n = 18) and probable dementia with Lewy bodies (DLB, n = 31) were studied and standardized by the calibration phantom method. Results: Linear regression equations between LE and ME collimators were obtained for the phantom study in all institutions. When the H/M ratio with an LE collimator was corrected based upon the calibration phantom, the corrected values were comparable to those obtained using ME collimators. The standard database also exhibited a normal distribution after standardization as determined by skewness and goodness-of-fit test. A mixture of the populations by LE and ME collimators showed significant separation of AD and DLB groups (F ratio = 24.9 for the late H/M), but the corrected values resulted in higher F ratios for both early and late H/M (F ratio = 34.9 for the late H/M). Conclusion: Standardization of H/M ratios by the heart-chest calibration phantom method is feasible among different collimator types. This method could be practically used for multicentre comparison of H/M ratios. © 2011 Springer-Verlag. | |||||