Iterative estimation of coherent-scattering profiles from given positions by use of a single-direction beam
http://hdl.handle.net/2297/32144
http://hdl.handle.net/2297/321442d68f450-e940-47f3-b5a8-fdc575cca223
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Iterative estimation of coherent-scattering profiles from given positions by use of a single-direction beam | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Terabe, Mitsuaki
× Terabe, Mitsuaki× Okamoto, Hiroyuki× Koshida, Kichiro |
|||||
書誌情報 |
Radiological Physics and Technology 巻 5, 号 2, p. 237-247, 発行日 2012-07-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12236881 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-012-0159-0 | |||||
出版者 | ||||||
出版者 | Japan Society of Medical Physics (JSMP) 日本放射線技術学会 / Springer Verlag (Germany) | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The coherent-scattering distribution is useful for characterization of materials in the medical field, and obtaining this information from a given position in the object is a useful new diagnostic approach. We propose a simpler geometric approach, which requires only a single-direction X-ray beam with no collimator in front of the detector. This method iteratively estimates coherent-scattering profiles from given positions along the beam path, based on the projections positioned at different object-to-detector distances. We confirmed the proposed calculation algorithm by numerical simulation and performed a simple experiment including attenuation correction. The accuracy of matching with the original profiles was dependent on the number of iterations, the distance between the first and second detectors, the distance between two objects, and the shape of the scattering profile. Whereas multiple scattering was the main problem in the experiment, the calculated scattering profiles matched well with the original profile. This technique indicates the feasibility of developing a coherent-scatter imaging system. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 発行後1年より全文公開 | |||||
権利 | ||||||
権利情報 | © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.jsrt.or.jp/ |