Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils

http://hdl.handle.net/2297/40390
http://hdl.handle.net/2297/40390
88fbc2af-17ed-4a15-b729-3609156aadad
名前 / ファイル ライセンス アクション
ME-PR-YAMASHIMA-T-59.pdf ME-PR-YAMASHIMA-T-59.pdf (9.6 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with Guglielmi detachable coils
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Uchiyama, Naoyuki

× Uchiyama, Naoyuki

WEKO 538
e-Rad 80293364
金沢大学研究者情報 80293364
研究者番号 80293364

Uchiyama, Naoyuki

Search repository
Kida, Shinya

× Kida, Shinya

WEKO 23656

Kida, Shinya

Search repository
Nomura, Motohiro

× Nomura, Motohiro

WEKO 23657

Nomura, Motohiro

Search repository
Hasegawa, Mitsuhiro

× Hasegawa, Mitsuhiro

WEKO 21831
e-Rad 70218460
研究者番号 70218460

Hasegawa, Mitsuhiro

Search repository
Yamashima, Tetsumori

× Yamashima, Tetsumori

WEKO 199
e-Rad 60135077
研究者番号 60135077

Yamashima, Tetsumori

Search repository
Yamashita, Junkoh

× Yamashita, Junkoh

WEKO 21834
e-Rad 90026948
研究者番号 90026948

Yamashita, Junkoh

Search repository
Matsui, Osamu

× Matsui, Osamu

WEKO 116
e-Rad 10019961
研究者番号 10019961

Matsui, Osamu

Search repository
書誌情報 Interventional Neuroradiology

巻 6, 号 SUPPL. 1, p. 59-63, 発行日 2000-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1591-0199
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 https://doi.org/10.1177/15910199000060s106
出版者
出版者 Japanese Society for Intravascular Neosurgery / Centauro srl
抄録
内容記述タイプ Abstract
内容記述 The purposes of this study are, firstly, to define the relationship between volume embolization ratio (VER) and degree of angiographical occlusion in endovascular treatment with Guglielmi detachable coils, and secondly, to examine influences of neck and dome sizes of aneurysms on the VER and the angiographical treatment result, and thirdly, to determine the relationship between the VER and the recanalization of coiled aneurysms. Fifty-two aneurysms in 46 patients were examined. VER ranged 8.1-31.9% (mean 18.5%). The mean VERs of each categories based on angiographical treatment results were 23.1% in complete occlusion, 16.1% in neck remnant and 12.2% in incomplete occlusion, respectively. The VER correlated significantly with both neck and dome size, while the angiographical treatment result was only affected by neck size. Five aneurysms showed aneurysmal recanalization among followed-up 41 aneurysms. All recanalized aneurysms were large, and their VERs were in range of 10.4-17.6%. Measurement of VER is useful to estimate the degree of occlusion objectively and to predict the aneurysmal recanalization. A small aneurysms with a small neck is relatively easy to achieve high VER and angiographical complete occlusion, with the consequence of less recanalization. On the other hand, a large aneurysm is liable to recanalize due to low VER, even if there was little filling of contrast medium in the aneurysmal cavity.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 12:15:42.855105
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3