Using breast radiographers' reports as a second opinion for radiologists' readings of microcalcifications in digital mammography

https://doi.org/10.24517/00014192
https://doi.org/10.24517/00014192
280689cf-bc6c-45ed-8769-82f3268628db
名前 / ファイル ライセンス アクション
ME-PR-TANAKA-R-20140565.pdf ME-PR-TANAKA-R-20140565.pdf (550.9 kB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Using breast radiographers' reports as a second opinion for radiologists' readings of microcalcifications in digital mammography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00014192
ID登録タイプ JaLC
著者 Tanaka, Rie

× Tanaka, Rie

WEKO 299
e-Rad 40361985
金沢大学研究者情報 40361985
研究者番号 40361985

Tanaka, Rie

Search repository
Takamori, Miho

× Takamori, Miho

WEKO 24373

Takamori, Miho

Search repository
Uchiyama, Yoshikazu

× Uchiyama, Yoshikazu

WEKO 24374

Uchiyama, Yoshikazu

Search repository
Nishikawa, Robert M.

× Nishikawa, Robert M.

WEKO 24375

Nishikawa, Robert M.

Search repository
Shiraishi, Junji

× Shiraishi, Junji

WEKO 24376

Shiraishi, Junji

Search repository
著者別表示 田中, 利恵

× 田中, 利恵

田中, 利恵

Search repository
書誌情報 British Journal of Radiology

巻 88, 号 1047, p. 20140565, 発行日 2015-03-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0007-1285
NCID
収録物識別子タイプ NCID
収録物識別子 AA00575096
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1259/bjr.20140565
出版者
出版者 British Institute of Radiology
抄録
内容記述タイプ Abstract
内容記述 Objective: The aim of this study was to investigate a practical method for incorporating radiographers' reports with radiologists' readings of digital mammograms. Methods: This simulation study was conducted using data from a free-response receiver operating characteristic observer study obtained with 75 cases (25 malignant, 25 benign and 25 normal cases) of digital mammograms. Each of the rating scores obtained by six breast radiographers was utilized as a second opinion for four radiologists' readings with the radiographers' reports. A logical "OR" operation with various criteria settings was simulated for deciding an appropriate method to select a radiographer's report in all combinations of radiologists and radiographers. The average figure of merit (FOM) of the radiologists' performances was statistically analysed using a jackknife procedure (JAFROC) to verify the clinical utility of using radiographers' reports. Results: Potential improvement of the average FOM of the radiologists' performances for identifying malignant microcalcifications could be expected when using radiographers' reports as a second opinion. When the threshold value of 2.6 in Breast Imaging-Reporting and Data System (BI-RADS®) assessment was applied to adopt/ reject a radiographer's report, FOMs of radiologists' performances were further improved. Conclusion: When using breast radiographers' reports as a second opinion, radiologists' performances potentially improved when reading digital mammograms. It could be anticipated that radiologists' performances were improved further by setting a threshold value on the BIRADS assessment provided by the radiographers. Advances in knowledge: For the effective use of a radiographer's report as a second opinion, radiographers' rating scores and its criteria setting for adoption/ rejection would be necessary.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 08:48:34.957128
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3