ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method

http://hdl.handle.net/2297/43457
http://hdl.handle.net/2297/43457
cbbed33f-4f0e-4331-8a02-df3c8d1df87a
名前 / ファイル ライセンス アクション
ME-PR-ICHIKAWA-K-374.pdf ME-PR-ICHIKAWA-K-374.pdf (786.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ichikawa, Katsuhiro

× Ichikawa, Katsuhiro

WEKO 646
e-Rad 40402630
金沢大学研究者情報 40402630
研究者番号 40402630

Ichikawa, Katsuhiro

Search repository
Hara, Takanori

× Hara, Takanori

WEKO 24531

Hara, Takanori

Search repository
Urikura, Atsushi

× Urikura, Atsushi

WEKO 24532

Urikura, Atsushi

Search repository
Takata, Tadanori

× Takata, Tadanori

WEKO 24533

Takata, Tadanori

Search repository
Ohashi, Kazuya

× Ohashi, Kazuya

WEKO 24534

Ohashi, Kazuya

Search repository
書誌情報 Physica Medica

巻 31, 号 4, p. 374-381, 発行日 2015-06-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1120-1797
NCID
収録物識別子タイプ NCID
収録物識別子 AA11064306
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.ejmp.2015.02.012
出版者
出版者 Associazione Italiana di Fisica Medica / Elsevier
抄録
内容記述タイプ Abstract
内容記述 The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5s, and for two R/. P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. © 2015 Associazione Italiana di Fisica Medica.
内容記述
内容記述タイプ Other
内容記述 Embargo Period 12 months
権利
権利情報 Copyright © Elsevier (CC-BY NC ND)
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連URI
識別子タイプ URI
関連識別子 http://www.elsevier.com/locate/issn/11201797
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:50:26.734621
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3