ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Cardiac 123I-MIBG Imaging for Clinical Decision Making: 22-Year Experience in Japan

http://hdl.handle.net/2297/43645
http://hdl.handle.net/2297/43645
48acae9e-5843-4a3a-b7e0-5dedfd0ba661
名前 / ファイル ライセンス アクション
ME-PR-NAKAJIMA-K-11S.pdf ME-PR-NAKAJIMA-K-11S.pdf (1.8 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Cardiac 123I-MIBG Imaging for Clinical Decision Making: 22-Year Experience in Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Nakajima, Kenichi

× Nakajima, Kenichi

WEKO 320
e-Rad 00167545
金沢大学研究者情報 00167545
研究者番号 00167545

Nakajima, Kenichi

Search repository
Nakata, Tomoaki

× Nakata, Tomoaki

WEKO 24546

Nakata, Tomoaki

Search repository
書誌情報 Journal of nuclear medicine : official publication, Society of Nuclear Medicine

巻 56, p. 11S-19S, 発行日 2015-06-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1535-5667
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.2967/jnumed.114.142794
出版者
出版者 Society of Nuclear Medicine
抄録
内容記述タイプ Abstract
内容記述 Cardiac neuroimaging with (123)I-metaiodobenzylguanidine ((123)I-MIBG) has been officially used in clinical practice in Japan since 1992. The nuclear cardiology guidelines of the Japanese Circulation Society, revised in 2010, recommended cardiac (123)I-MIBG imaging for the management of heart failure (HF) patients, particularly for the assessment of HF severity and prognosis of HF patients. Consensus in North American and European countries regarding incorporation into clinical practice, however, has not been established yet. This article summarizes 22 y of clinical applications in Japan of (123)I-MIBG imaging in the field of cardiology; these applications are reflected in cardiology guidelines, including recent methodologic advances. A standardized cardiac (123)I-MIBG parameter, the heart-to-mediastinum ratio (HMR), is the basis for clinical decision making and enables common use of parameters beyond differences in institutions and studies. Several clinical studies unanimously demonstrated its potent independent roles in prognosis evaluation and risk stratification irrespective of HF etiologies. An HMR of less than 1.6-1.8 and an accelerated washout rate are recognized as high-risk indicators of pump failure death, sudden cardiac death, and fatal arrhythmias and have independent and incremental prognostic values together with known clinical variables, such as left ventricular ejection fraction and brain natriuretic peptide. Another possible use of this imaging technique is the selection of therapeutic strategy, such as pharmacologic treatment and nonpharmacologic treatment with an implantable cardioverter-defibrillator or cardiac resynchronization device; however, this possibility remains to be investigated. Recent multiple-cohort database analyses definitively demonstrated that patients who were at low risk for lethal events and who were defined by an HMR of greater than 2.0 on (123)I-MIBG studies had a good long-term prognosis. Future investigations of cardiac (123)I-MIBG imaging will contribute to better risk stratification of low-risk and high-risk populations, to the establishment of cost-effective use of this imaging technique for the management of HF patients, and to worldwide acceptance of this imaging technique in clinical cardiology practice. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
権利
権利情報 © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 16:58:10.792442
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3