ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Quantitative analysis of the Trendelenburg test and invention of a modified method

http://hdl.handle.net/2297/46797
http://hdl.handle.net/2297/46797
46211a50-8efe-4469-aa61-851379da95dc
名前 / ファイル ライセンス アクション
ME-PR-FUJITA-K-81.pdf ME-PR-FUJITA-K-81.pdf (1.5 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-12-05
タイトル
タイトル Quantitative analysis of the Trendelenburg test and invention of a modified method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Fujita, Kenji

× Fujita, Kenji

WEKO 1155
金沢大学研究者情報 40271043
研究者番号 40271043

Fujita, Kenji

Search repository
Kabata, Tamon

× Kabata, Tamon

WEKO 23450
e-Rad 10334749
研究者番号 10334749

Kabata, Tamon

Search repository
Kajino, Yoshitomo

× Kajino, Yoshitomo

WEKO 24602
金沢大学研究者情報 60622884
研究者番号 60622884

Kajino, Yoshitomo

Search repository
Iwai, Shintaro

× Iwai, Shintaro

WEKO 68921

Iwai, Shintaro

Search repository
Kuroda, Kazunari

× Kuroda, Kazunari

WEKO 68922

Kuroda, Kazunari

Search repository
Hasegawa, Kazuhiro

× Hasegawa, Kazuhiro

WEKO 1336
研究者番号 60324159

Hasegawa, Kazuhiro

Search repository
Fujiwara, Katsuo

× Fujiwara, Katsuo

WEKO 7574
研究者番号 60190089

Fujiwara, Katsuo

Search repository
Tsuchiya, Hiroyuki

× Tsuchiya, Hiroyuki

WEKO 151
e-Rad 40227434
金沢大学研究者情報 40227434
研究者番号 40227434

Tsuchiya, Hiroyuki

Search repository
書誌情報 Journal of Orthopaedic Science

巻 22, 号 1, p. 81-88, 発行日 2017-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0949-2658
NCID
収録物識別子タイプ NCID
収録物識別子 AA11052566
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.jos.2016.09.007
出版者
出版者 The Japanese Orthopaedic Association = 日本整形外科学会 / Springer Verlag
抄録
内容記述タイプ Abstract
内容記述 Background While the Trendelenburg test has been used for 120 years to detect hip abductor muscle weakness, the methodology has not been standardised. Purposes This study undertook to quantitatively analyze the relation between abductor muscle activity and pelvic tilt angle in the Trendelenburg one-leg stance, examine the pitfalls associated with performing the T-test, and develop a modified method that will produce reliable results. Methods A convenience sample of 15 healthy males was asked to assume a one-leg stance in ten different postures, five with mild flexion on the unsupported side, and five with severe flexion. Trunk sway angle, pelvic tilt angle, and the pelvic on femur (POF) angle were measured for each posture. Statistical analysis was used to assess differences in hip abductor activity and public tilt angle between the control posture and the test postures. Results With minimum trunk sway, hip abductor muscle activity increases when the pelvis is elevated and decreases when it is dropped. With trunk sway toward the test side, abductor muscle activity decreased when the pelvis was elevated; with trunk sway toward the non-test side, muscle activity stayed approximately constant when the pelvis was dropped. Conclusions Based on the results we developed a modified T-test methodology that would improve reliability. This test should be performed with minimum trunk sway and severe flexion on the non-test side. The assessment of muscle weakness is based on whether the patient can keep the single-leg standing posture when forced to elevate the pelvis, not simply on the pelvic drop. In future research, we will perform the modified T-test on patients with a suspected hip abductor deficiency, and assess the usefulness of the modified test. © 2016 The Japanese Orthopaedic Association
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 17:46:57.369431
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3