ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

A metric for evaluation of deformable image registration

http://hdl.handle.net/2297/42224
http://hdl.handle.net/2297/42224
95d1f81c-c7ac-413d-8366-aae71e174d4a
名前 / ファイル ライセンス アクション
ME-PR-TAKEMURA-A-2014.pdf ME-PR-TAKEMURA-A-2014.pdf (215.0 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル A metric for evaluation of deformable image registration
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Takemura, Akihiro

× Takemura, Akihiro

WEKO 529
e-Rad 70313674
金沢大学研究者情報 70313674
研究者番号 70313674

Takemura, Akihiro

Search repository
Kojima, Hironori

× Kojima, Hironori

WEKO 24776

Kojima, Hironori

Search repository
Ueda, Shinichi

× Ueda, Shinichi

WEKO 24777

Ueda, Shinichi

Search repository
Isomura, Naoki

× Isomura, Naoki

WEKO 24778

Isomura, Naoki

Search repository
Noto, Kimiya

× Noto, Kimiya

WEKO 24779

Noto, Kimiya

Search repository
書誌情報 SPIE Proceedings

巻 9415, p. 941520, 発行日 2015-03-18
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1117/12.2081846
出版者
出版者 SPIE
抄録
内容記述タイプ Abstract
内容記述 We propose a new metric, local uncertainty (LU), for the evaluation of deformable image registration (DIR) for dose accumulation in radiotherapy. LU measures the uncertainty of placement of each voxel in an image set after a DIR. The underlying concept of LU is that the distance between a focused voxel and a surrounding voxel on an image feature such as an edge is unchanged locally when the organ that includes these voxels is deformed. A candidate for the focused voxel after DIR can be calculated from three surrounding voxels and their distances. The positions of the candidates of the focused voxel calculated from several groups of any three surrounding voxels would vary. The variation of candidate positions indicates uncertainty of the focused voxel position. Thus, the standard deviation of candidate positions is treated as an LU value. The LU can be calculated in uniform signal regions. Assessment of DIR results in such regions is important for dose accumulation. The LU calculation was applied to a pair of computed tomography (CT) head and neck examinations after DIR. These CT examinations were for the initial radiotherapy planning and re-planning for a treatment course where the tumor underwent shrinkage during treatment. We generated an LU image showing high LU values in the shrinking tumor region and low LU values in undeformable bone. We have proposed the LU as a new metric for DIR.
権利
権利情報 © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:49:04.199851
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3