WEKO3
インデックスリンク
アイテム
Effects of Iodinated Contrast Agent on Diffusion Weighted Magnetic Resonance Imaging
http://hdl.handle.net/2297/19553
http://hdl.handle.net/2297/1955305b69ae2-06a7-4873-807d-cd06105dd966
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Effects of Iodinated Contrast Agent on Diffusion Weighted Magnetic Resonance Imaging | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Ogura, Akio
× Ogura, Akio× Hayakawa, Katsumi× Miyati, Tosiaki× Maeda, Fumie |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 京都市立病院 | |||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
Academic Radiology 巻 16, 号 10, p. 1196-1200, 発行日 2009-10-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1076-6332 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11053376 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.acra.2009.03.021 | |||||
出版者 | ||||||
出版者 | Elsevier / AUR Published by Elsevier | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Rationale and Objectives: To evaluate the effects of iodine contrast agent on diffusion signal intensity and apparent diffusion coefficient (ADC) in diffusion-weighted imaging (DWI) studies in magnetic resonance imaging (MRI) examination just after computed tomography (CT) contrast imaging. Materials and Methods: On a 1.5 T MRI scanner, ADC was calculated from the signal intensity of DWI (b = 0 and 1000) using phantoms filled with contrast agent (0, 4.5, 6.0, 9.0, 30, and 60 mgI/mL). We evaluated the signal intensities of DWI and ADC in 10 patients (3 women, 7 men, 35-68 years old) examined by MRI study less than 40 minutes after injection of 100 mL of iopamidol (300 mgI/mL) for CT study. Results: The DWI signal increased until a CT value of 190 HU, but showed no changes above this value. The ADC decreased with increases in CT value. Less than 40 minutes after injection of iopamidol (300 mgI/mL) for CT scan, the signal intensity of DWI was significantly increased and ADC was significantly decreased. Conclusions: It is necessary to recognize the rate of decrease of ADC, because it is dependent on the density of iodine contrast agents. © 2009 AUR. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/10766332 |