ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. C. 医薬保健学域; 医学類・薬学類・医薬科学類・保健学類
  2. c 10. 学術雑誌掲載論文(医・保健)
  3. 1. 査読済論文(医学・保健)

Noise reduction effect in super-high resolution LCDs using independent sub-pixel driving technology

http://hdl.handle.net/2297/10941
http://hdl.handle.net/2297/10941
d744bf29-7070-46d4-8b9f-c4c0be7982bf
名前 / ファイル ライセンス アクション
ME-PR-ICHIKAWA-K-69171F.pdf ME-PR-ICHIKAWA-K-69171F.pdf (899.3 kB)
Item type 会議発表論文 / Conference Paper(1)
公開日 2017-10-03
タイトル
タイトル Noise reduction effect in super-high resolution LCDs using independent sub-pixel driving technology
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
著者 Ichikawa, Katsuhiro

× Ichikawa, Katsuhiro

WEKO 646
e-Rad 40402630
金沢大学研究者情報 40402630
研究者番号 40402630

Ichikawa, Katsuhiro

Search repository
Nishi, Yoshikazu

× Nishi, Yoshikazu

WEKO 25838

Nishi, Yoshikazu

Search repository
Hayashi, Shigeo

× Hayashi, Shigeo

WEKO 25839

Hayashi, Shigeo

Search repository
Hasegawa, Mikio

× Hasegawa, Mikio

WEKO 25840

Hasegawa, Mikio

Search repository
Kodera, Yoshie

× Kodera, Yoshie

WEKO 25841

Kodera, Yoshie

Search repository
書誌情報 Progress in Biomedical Optics and Imaging - Proceedings of SPIE

巻 6917, 発行日 2008-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1605-7422
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1117/12.770848
出版者
出版者 International Society for Optical Engineering (SPIE)
抄録
内容記述タイプ Abstract
内容記述 We have developed and reported a super-high resolution liquid crystal display (SHR-LCD) using a new resolution enhancement technology of the independent sub-pixel driving (ISD) that utilizes three sub-pixels in each pixel element. This technology realizes the three-times resolution enhancement of monochrome LCDs, and improves the depiction ability of detailed shape such as micro-calcifications of a mammography and bone structures. Furthermore, the ISD technology brings not only resolution enhancement but also noise reduction effect by the high-resolution data sampling in displaying the clinical images. In this study, we examined the efficacy of the newly developed LCDs from the noise power spectrum measurement (NPS), the perceptual comparison of the phantom images and the clinical images. A 15 mega-pixel (MP)SHR-LCD out of a 5MP LCD and a 6MP SHR-LCD out of a 2MP LCD were used for the measurement and the evaluation. In the NPS measurements, the noise of all the SHR-LCDs was improved obviously. The improvement degree of the NPS varied according to the sub-sampling ratio of the data sampling implemented during the image displaying, and the 6MP LCD showed higher improvement. In the perceptual evaluation of the quality-control phantom images and the low-contrast images of the micro-calcifications of the mammography, all the SHR-LCDs provided higher performance than the conventional LCDs. These results proved that the SHR-LCDs using the ISD technology had the excellent ability to display the high-resolution clinical images.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
シリーズ
関連名称 69171F
戻る
0
views
See details
Views