Effect of daily setup errors on individual dose distribution in conventional radiotherapy: An initial study

http://hdl.handle.net/2297/19140
http://hdl.handle.net/2297/19140
9f7faca6-c138-4eb6-9171-5d7b529139ec
名前 / ファイル ライセンス アクション
ME-PR-TAKEMURA-A-151.pdf ME-PR-TAKEMURA-A-151.pdf (552.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Effect of daily setup errors on individual dose distribution in conventional radiotherapy: An initial study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Takemura, Akihiro

× Takemura, Akihiro

WEKO 529
e-Rad 70313674
金沢大学研究者情報 70313674
研究者番号 70313674

Takemura, Akihiro

Search repository
Shoji, Saori

× Shoji, Saori

WEKO 25907

Shoji, Saori

Search repository
Ueda, Shinichi

× Ueda, Shinichi

WEKO 25908

Ueda, Shinichi

Search repository
Kurata, Yuichi

× Kurata, Yuichi

WEKO 25909

Kurata, Yuichi

Search repository
Kumano, Tomoyasu

× Kumano, Tomoyasu

WEKO 25910
e-Rad 20377386

Kumano, Tomoyasu

Search repository
Takamatsu, Shigeyuki

× Takamatsu, Shigeyuki

WEKO 25911

Takamatsu, Shigeyuki

Search repository
Suzuki, Masayuki

× Suzuki, Masayuki

WEKO 693
研究者番号 70111325

Suzuki, Masayuki

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学医薬保健研究域保健学系
書誌情報 Radiological Physics and Technology

巻 2, 号 2, p. 151-158, 発行日 2009-07-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1865-0333
NCID
収録物識別子タイプ NCID
収録物識別子 AA12236881
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s12194-009-0059-0
出版者
出版者 Japanese Society of Radiological Technology and Japan Society of Medical Physics = 日本放射線技術学会&医学物理学会
抄録
内容記述タイプ Abstract
内容記述 Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9-35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3-1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5-10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 00:43:55.543685
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3