WEKO3
インデックスリンク
アイテム
Effect of daily setup errors on individual dose distribution in conventional radiotherapy: An initial study
http://hdl.handle.net/2297/19140
http://hdl.handle.net/2297/191409f7faca6-c138-4eb6-9171-5d7b529139ec
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Effect of daily setup errors on individual dose distribution in conventional radiotherapy: An initial study | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Takemura, Akihiro
× Takemura, Akihiro× Shoji, Saori× Ueda, Shinichi× Kurata, Yuichi× Kumano, Tomoyasu× Takamatsu, Shigeyuki× Suzuki, Masayuki |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学医薬保健研究域保健学系 | |||||
書誌情報 |
Radiological Physics and Technology 巻 2, 号 2, p. 151-158, 発行日 2009-07-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1865-0333 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12236881 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12194-009-0059-0 | |||||
出版者 | ||||||
出版者 | Japanese Society of Radiological Technology and Japan Society of Medical Physics = 日本放射線技術学会&医学物理学会 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradiated in the neck, esophagus, and pelvic area were obtained retrospectively. We found that the maximum dose variances for the three cases were 19.9-35.9%. The maximum dose variance points were relatively far from the isocenter. The volume of the 10% dose difference had widths of 1.3-1.85 cm around the beam edges. The V95 and mean doses at the clinical target volume were mostly unchanged. Doses around the beam edges were more varied than those around the isocenter for every case. The dose on the spinal cord located near the beam edges varied by 5-10% compared with the dose of the radiotherapy plan in two of the cases. We demonstrated the individual dose distributions of the cases affected by daily setup errors for all fractions. © 2009 Japanese Society of Radiological Technology and Japan Society of Medical Physics. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |