眼上鏡式上下反転視実験(金沢'92) : 自己の身体が見えることの意味

http://hdl.handle.net/2297/5138
http://hdl.handle.net/2297/5138
521662ae-a3b4-4f2c-8f4f-a33b051d4a47
名前 / ファイル ライセンス アクション
KJ00000706556.pdf KJ00000706556.pdf (2.0 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2017-10-02
タイトル
タイトル 眼上鏡式上下反転視実験(金沢'92) : 自己の身体が見えることの意味
タイトル
タイトル An up-down reversed vision experiment using a mirror device set above the eyes : How does it facilitate the upright vision when the subject can easily see his own body?
言語 en
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 吉村, 浩一

× 吉村, 浩一

WEKO 4856
e-Rad 70135490

吉村, 浩一

Search repository
著者別表示 Yoshimura, Hirokazu

× Yoshimura, Hirokazu

WEKO 4856
e-Rad 70135490

Yoshimura, Hirokazu

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学文学部
書誌情報 金沢大学文学部論集. 行動科学科篇

巻 13, p. 1-34, 発行日 1993-03-20
ISSN
収録物識別子タイプ ISSN
収録物識別子 0285-6514
NCID
収録物識別子タイプ NCID
収録物識別子 AN00044477
抄録
内容記述タイプ Abstract
内容記述 Using the Kohler-type (mirror-type) device, an up-down reversed vision experiment was conducted. This experiment was named Kanazawa '92 Experiment. The author was the subject and the device was worn for a total of 200 hours during the 14-day period. The purpose of the experiment was to compare the effects of this type device with those of the rectangle prism-type goggles recorded two years earlier. The two experiments were conducted in similar manners : the same subject, duration, and environment, the only difference being direction of the field of view. With the mirror-type device, the subject can see himself easily, but with the prism-type goggles, he had to bend over to see his body. If the ability of the subject to see himself is important for visual adaptation to the visually-transposed world, the mirror-type device should be advantageous. The data of the experiment are composed of the subject's direct observations of daily perception and performance, and the results of ten different tests conducted every 3 days. The results are as follows. (1) With the mirror-type device, the subject maintained continuous vision using the three points of view ; looking straight ahead, looking ahead at a 45 degree angle, and looking directly down. (2) He was able to perform many kinds of visual-motor tasks smoothly, employing the visual frame of reference. (3) He saw objects right side up in these frames of visual reference, but they were not consistent with his bodily sense. In conclusion, his vision is normal in reference to what he saw, but not right side up in reference to what he felt.
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 12:35:18.472466
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3