ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. G. 附属病院
  2. g 10. 学術雑誌掲載論文
  3. 1. 査読済論文

Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects

http://hdl.handle.net/2297/43922
http://hdl.handle.net/2297/43922
1b778328-4dc7-467a-9305-fb08819eb38e
名前 / ファイル ライセンス アクション
HO-PR-MATSUO-S-452.pdf HO-PR-MATSUO-S-452.pdf (559.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-05
タイトル
タイトル Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Matsuo, Shinro

× Matsuo, Shinro

WEKO 599
金沢大学研究者情報 30359773
研究者番号 30359773

Matsuo, Shinro

Search repository
Nakajima, Kenichi

× Nakajima, Kenichi

WEKO 320
e-Rad 00167545
金沢大学研究者情報 00167545
研究者番号 00167545

Nakajima, Kenichi

Search repository
Onoguchi, Masahisa

× Onoguchi, Masahisa

WEKO 352
金沢大学研究者情報 30283120
研究者番号 30283120

Onoguchi, Masahisa

Search repository
Wakabayashi, Hiroshi

× Wakabayashi, Hiroshi

WEKO 489
金沢大学研究者情報 60622818
研究者番号 60622818

Wakabayashi, Hiroshi

Search repository
Okuda, Koichi

× Okuda, Koichi

WEKO 45592

Okuda, Koichi

Search repository
Kinuya, Seigo

× Kinuya, Seigo

WEKO 115
e-Rad 20281024
金沢大学研究者情報 20281024
研究者番号 20281024

Kinuya, Seigo

Search repository
書誌情報 Annals of Nuclear Medicine

巻 29, 号 5, p. 452-459, 発行日 2015-06-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
NCID
収録物識別子タイプ NCID
収録物識別子 AA10708017
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s12149-015-0965-7
出版者
出版者 The Japanese Society of Nuclear Medicine = 日本核医学会 / Springer-Verlag Tokyo
抄録
内容記述タイプ Abstract
内容記述 Objective A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 (201Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Methods Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering201Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. Results IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p˂0.05). The left ventricular ejection fraction from IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). Conclusion The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR. The results indicated that the IQ-SPECT system with AC is capable of correcting inferior artifacts with high image quality. © The Japanese Society of Nuclear Medicine 2015.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
シリーズ
関連名称 A008
関連URI
識別子タイプ URI
関連識別子 http://www.jsnm.org/jsnm/2015
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 21:15:55.741690
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3