WEKO3
インデックスリンク
アイテム
Comparison of diagnostic value of I-123 MIBG and high-dose I-131 MIBG scintigraphy including incremental value of SPECT/CT over planar image in patients with malignant pheochromocytoma/paraganglioma and neuroblastoma
http://hdl.handle.net/2297/26393
http://hdl.handle.net/2297/263939855dcb1-f759-48c3-b050-4bb1a342b5af
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-05 | |||||
タイトル | ||||||
タイトル | Comparison of diagnostic value of I-123 MIBG and high-dose I-131 MIBG scintigraphy including incremental value of SPECT/CT over planar image in patients with malignant pheochromocytoma/paraganglioma and neuroblastoma | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Fukuoka, Makoto
× Fukuoka, Makoto× Taki, Junichi× Mochizuki, Takafumi× Kinuya, Seigo |
|||||
提供者所属 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 金沢大学附属病院核医学診療科 | |||||
書誌情報 |
Clinical Nuclear Medicine 巻 36, 号 1, p. 1-7, 発行日 2011-01-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0363-9762 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA0060791X | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1097/RLU.0b013e3181feeb5e | |||||
出版者 | ||||||
出版者 | Lippincott Williams & Wilkins | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To compare lesion detectability of I-123 MIBG scintigraphy with that of high-dose I-131 MIBG and to evaluate incremental benefit of SPECT/CT over planar image for the detection and localization of the lesions in patients with I-131 MIBG therapy for malignant pheochromocytoma/paraganglioma and neuroblastoma. Materials and Methods: We retrospectively investigated 16 patients with malignant pheochromocytoma/paraganglioma and neuroblastoma, who were referred for I-131 MIBG therapy. We investigated the lesion detectability in 10 pairs of I-123 and high-dose I-131 MIBG studies of the same patient, obtained within 2 weeks. In 31 studies of I-123 MIBG scintigraphy in 16 patients and 17 studies of high-dose I-131 MIBG scintigraphy in 12 patients, we compared planar and SPECT/CT images for the lesion detectability and localization. Results: The number of lesions detected by I-123 MIBG planer image and SPECT/CT and high-dose planer I-131 MIBG and SPECT/CT were 3.0 and 3.7, 7.3 and 7.7 per study, respectively. SPECT/CT images provided additional diagnostic information over planar images in 25 studies (81%) of 12 patients (75%) in I-123 MIBG scintigraphy and in 9 studies (53%) of 9 patients (75%) in high-dose I-131 MIBG scintigraphy. CONCLUSION: Post-therapy high-dose I-131 MIBG scintigraphy is superior to I-123 MIBG scintigraphy in lesion detectability even in comparison with I-123 MIBG SPECT/CT images and high-dose I-131 MIBG planar images in patients with malignant neuroendocrine tumors. SPECT/CT images are helpful for accurate identification of anatomic localization compared with planar images. Copyright © Lippincott Williams & Wilkins. | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |