Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy

https://doi.org/10.24517/00039998
https://doi.org/10.24517/00039998
b306798a-02eb-4a3c-ba48-a1085a41841a
名前 / ファイル ライセンス アクション
FR-PR-FUKUMA-T-23707.pdf FR-PR-FUKUMA-T-23707.pdf (370.0 kB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-06
タイトル
タイトル Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00039998
ID登録タイプ JaLC
著者 Fukuma, Takeshi

× Fukuma, Takeshi

WEKO 366
e-Rad 90452094
金沢大学研究者情報 90452094
研究者番号 90452094

Fukuma, Takeshi

Search repository
著者別表示 福間, 剛士

× 福間, 剛士

福間, 剛士

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学フロンティアサイエンス機構
書誌情報 Review of Scientific Instruments

巻 80, 号 2, p. 023707, 発行日 2009-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
NCID
収録物識別子タイプ NCID
収録物識別子 AA00817730
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1063/1.3086418
出版者
出版者 American Institute of Physics
抄録
内容記述タイプ Abstract
内容記述 I developed a wideband low-noise optical beam deflection sensor with a photothermal cantilever excitation system for liquid-environment atomic force microscopy. The developed sensor has a 10 MHz bandwidth and 4.7 fm/Hz deflection noise density in water. The theoretically limited noise performance (i.e., the noise level limited only by the photodiode shot noise) has been achieved in liquid for the first time. Owing to the wide bandwidth and the replaceable focus lens design, the sensor is applicable to cantilevers with various dimensions. The deflection noise densities of less than 7.8 fm/Hz have been achieved in water for cantilevers with lengths from 35 to 125 μm. The ideal amplitude and phase versus frequency curves without distortion are obtained with the developed photothermal excitation system. The excitation system is applicable to relatively stiff cantilevers (>20 N/m) in liquid, making it possible to obtain true atomic-resolution images in liquid. True atomic-resolution imaging of mica in water is demonstrated using the developed deflection sensor and the photothermal excitation system. © 2009 American Institute of Physics.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 10:35:21.684963
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3