Characteristics of iodine-123 IQ-SPECT/CT imaging compared with conventional SPECT/CT.

https://doi.org/10.24517/00053810
https://doi.org/10.24517/00053810
b99f5f90-8d6a-49a1-903a-afea4482facc
名前 / ファイル ライセンス アクション
ME-PR-SHIBUTANI-T-103.pdf ME-PR-SHIBUTANI-T-103.pdf (964.6 kB)
license.icon
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-04-25
タイトル
タイトル Characteristics of iodine-123 IQ-SPECT/CT imaging compared with conventional SPECT/CT.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
ID登録
ID登録 10.24517/00053810
ID登録タイプ JaLC
著者 Shibutani, Takayuki

× Shibutani, Takayuki

WEKO 84176
e-Rad 80762509

Shibutani, Takayuki

Search repository
Onoguchi, Masahisa

× Onoguchi, Masahisa

WEKO 20906
e-Rad 30283120

Onoguchi, Masahisa

Search repository
Yoneyama, Hiroto

× Yoneyama, Hiroto

WEKO 84178

Yoneyama, Hiroto

Search repository
Konishi, Takahiro

× Konishi, Takahiro

WEKO 84179

Konishi, Takahiro

Search repository
Matsuo, Shinro

× Matsuo, Shinro

WEKO 77700
e-Rad 30359773

Matsuo, Shinro

Search repository
Nakajima, Kenichi

× Nakajima, Kenichi

WEKO 320
e-Rad 00167545
金沢大学研究者情報 00167545
研究者番号 00167545

Nakajima, Kenichi

Search repository
著者別表示 澁谷, 孝行

× 澁谷, 孝行

澁谷, 孝行

Search repository
松尾, 信郎

× 松尾, 信郎

松尾, 信郎

Search repository
中嶋, 憲一

× 中嶋, 憲一

中嶋, 憲一

Search repository
提供者所属
内容記述タイプ Other
内容記述 金沢大学医薬保健研究域保健学系
書誌情報 Annals of Nuclear Medicine

巻 33, 号 2, p. 103-111, 発行日 2019-02-25
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
NCID
収録物識別子タイプ NCID
収録物識別子 AA10708017
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s12149-018-1310-8
出版者
出版者 日本核医学会 = Japanese Society of Nuclear Medicine
抄録
内容記述タイプ Abstract
内容記述 Objectives
Although the utility of IQ-SPECT imaging using 99mTc and 201Tl myocardial perfusion SPECT has been reported, 123I-labeled myocardial SPECT has not been fully evaluated. We determined the characteristics and utility of 123I IQ-SPECT imaging compared with conventional SPECT (C-SPECT).
Methods
Two myocardial phantom patterns were used to simulate normal myocardium and myocardial infarction. SPECT acquisition was performed using a hybrid dual-head SPECT/CT system equipped with a SMARTZOOM collimator for IQ-SPECT or a low-medium energy general purpose collimator for C-SPECT. Projection data were reconstructed using ordered subset expectation maximization with depth-dependent 3-dimensional resolution recovery for C-SPECT and ordered subset conjugate gradient minimizer method for IQ-SPECT. Three types of myocardial image were created; namely, no correction (NC), with attenuation correction (AC), and with both attenuation and scatter corrections (ACSC). Five observers visually scored the homogeneity of normal myocardium and defect severity of the myocardium with inferior defects by a five-point scale: homogeneity scores (5 = homogeneous to 1 = inhomogeneous) and defect scores (5 = excellent to 1 = poor). We also created a 17-segment polar map and quantitatively assessed segmental %uptake using a myocardial phantom with normal findings and defects.
Results
The average visual homogeneity scores of the IQ-SPECT with NC and ACSC were significantly higher than that of C-SPECT, whereas the average visual defect scores of IQ-SPECT with AC and ACSC were significantly lower. The %uptake of all segments for IQ-SPECT with NC was significantly higher than that of C-SPECT. Furthermore, the subtraction of %uptake for C-SPECT and IQ-SPECT was the largest in inferior wall, which was approximately 10.1%, 14.7% and 14.4% for NC, AC and ACSC, respectively. The median % uptake values of the inferior wall with defect areas for C-SPECT and IQ-SPECT were 46.9% and 50.7% with NC, 59.8% and 69.2% with AC, and 54.7% and 66.5% with ACSC, respectively.
Conclusion
123I IQ-SPECT imaging significantly improved the attenuation artifact compared with C-SPECT imaging. Although the defect detectability of IQ-SPECT was inferior to that of C-SPECT, 123I IQ-SPECT images with NC and ACSC met the criteria for defect detectability. Use of 123I IQ-SPECT is suitable for routine examinations.
内容記述
内容記述タイプ Other
内容記述 Embargo Period 12 months
権利
権利情報 Copyright © 日本核医学会 Japanese Society of Nuclear Medicine
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連URI
識別子タイプ URI
関連識別子 https://link.springer.com/article/10.1007%2Fs12149-018-1310-8
関連名称 https://link.springer.com/article/10.1007%2Fs12149-018-1310-8
関連URI
識別子タイプ URI
関連識別子 http://www.jsnm.org/
関連名称 http://www.jsnm.org/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-27 16:32:32.020300
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3