WEKO3
インデックスリンク
アイテム
Wearable electromyography measurement system using cable-free network system on conductive fabric
https://doi.org/10.24517/00007806
https://doi.org/10.24517/000078060390c281-4886-4254-8502-4c1a7086b0ed
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 学術雑誌論文 / Journal Article(1) | |||||||
---|---|---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||||
タイトル | ||||||||
タイトル | Wearable electromyography measurement system using cable-free network system on conductive fabric | |||||||
言語 | ||||||||
言語 | eng | |||||||
資源タイプ | ||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||
資源タイプ | journal article | |||||||
ID登録 | ||||||||
ID登録 | 10.24517/00007806 | |||||||
ID登録タイプ | JaLC | |||||||
著者 |
Akita, Junichi
× Akita, Junichi× Shinmura, Toru× Sakurazawa, Shigeru× Yanagihara, Keisuke× Kunita, Mihoko× Toda, Masashi× Iwata, Kunio |
|||||||
著者別表示 |
秋田, 純一
× 秋田, 純一
|
|||||||
提供者所属 | ||||||||
内容記述タイプ | Other | |||||||
内容記述 | 金沢大学融合研究域融合科学系 / 金沢大学大学院自然科学研究科情報システム | |||||||
書誌情報 |
Artificial Intelligence in Medicine 巻 42, 号 2, p. 99-108, 発行日 2008-02-01 |
|||||||
ISSN | ||||||||
収録物識別子タイプ | ISSN | |||||||
収録物識別子 | 0933-3657 | |||||||
NCID | ||||||||
収録物識別子タイプ | NCID | |||||||
収録物識別子 | AA10706135 | |||||||
DOI | ||||||||
関連タイプ | isVersionOf | |||||||
識別子タイプ | DOI | |||||||
関連識別子 | 10.1016/j.artmed.2007.11.003 | |||||||
出版者 | ||||||||
出版者 | Elsevier | |||||||
抄録 | ||||||||
内容記述タイプ | Abstract | |||||||
内容記述 | Objective: To solve the complicated wires and battery maintenance problems in the application of wearable computing for biomedical monitoring, the electromyography (EMG) measurement system using conductive fabric for power supply and electric shield for noise reduction is proposed. Material and methods: The basic cable-free network system using conductive fabric, named as "TextileNet" is developed. The conductive fabric has the function of electric shield for noise reduction in EMG measurement, and it enables the precise EMG measurement with wearable system. Results: The specifications of the developed prototype TextileNet system using wear with conductive fabric were communication speed of 9600 bit/s and power supply of 3 W for each device. The electric shield effect was evaluated for precise EMG measurement, and the shield efficacy of conductive fabric was estimated as high as that of shield room. Conclusions: TextileNet system solves both the problems of complicated wires and battery maintenance in wearable computing systems. Conductive fabric used in TextileNet system is also effective for precise EMG measurement as electric shield. The combination of TextileNet system and EMG measurement device will implement the cable-free, battery-free wearable EMG measurement system. © 2007 Elsevier B.V. All rights reserved. | |||||||
著者版フラグ | ||||||||
出版タイプ | AM | |||||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |