Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion

http://hdl.handle.net/2297/36506
http://hdl.handle.net/2297/36506
861626fd-2802-4e7d-9052-3f4181cd8538
名前 / ファイル ライセンス アクション
TE-PR-MATSUMURA-K-1724.pdf TE-PR-MATSUMURA-K-1724.pdf (443.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Lee, Jihyoung

× Lee, Jihyoung

WEKO 12077

Lee, Jihyoung

Search repository
Matsumura, Kenta

× Matsumura, Kenta

WEKO 11933
e-Rad 30510383
研究者番号 30510383

Matsumura, Kenta

Search repository
Yamakoshi, Ken-ichi

× Yamakoshi, Ken-ichi

WEKO 42
e-Rad 40014310
研究者番号 40014310

Yamakoshi, Ken-ichi

Search repository
Rolfe, Peter

× Rolfe, Peter

WEKO 12078

Rolfe, Peter

Search repository
Tanaka, Shinobu

× Tanaka, Shinobu

WEKO 78
e-Rad 40242218
金沢大学研究者情報 40242218
研究者番号 40242218

Tanaka, Shinobu

Search repository
Yamakoshi, Takehiro

× Yamakoshi, Takehiro

WEKO 10974
e-Rad 70444205
研究者番号 70444205

Yamakoshi, Takehiro

Search repository
書誌情報 Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS

巻 2013, 号 6609852, p. 1724-1727, 発行日 2013-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 1557-170X
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1109/EMBC.2013.6609852
出版者
出版者 IEEE
抄録
内容記述タイプ Abstract
内容記述 Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life. © 2013 IEEE.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 02:07:51.141666
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3