ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(工)

Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring

http://hdl.handle.net/2297/34137
http://hdl.handle.net/2297/34137
a66632e2-e2be-43b5-b347-632ee0c4269d
名前 / ファイル ライセンス アクション
ME-PR-MATSUMURA-K-359.pdf ME-PR-MATSUMURA-K-359.pdf (585.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Lee, Jihyoung

× Lee, Jihyoung

WEKO 12180

Lee, Jihyoung

Search repository
Matsumura, Kenta

× Matsumura, Kenta

WEKO 12181

Matsumura, Kenta

Search repository
Yamakoshi, Takehiro

× Yamakoshi, Takehiro

WEKO 10974
e-Rad 70444205
研究者番号 70444205

Yamakoshi, Takehiro

Search repository
Rolfe, Peter

× Rolfe, Peter

WEKO 12182

Rolfe, Peter

Search repository
Tanaka, Naoto

× Tanaka, Naoto

WEKO 12183

Tanaka, Naoto

Search repository
Kim, Kyungho

× Kim, Kyungho

WEKO 12184

Kim, Kyungho

Search repository
Yamakoshi, Ken-ichi

× Yamakoshi, Ken-ichi

WEKO 42
e-Rad 40014310
研究者番号 40014310

Yamakoshi, Ken-ichi

Search repository
書誌情報 Physiological Measurement

巻 34, 号 3, p. 359-375, 発行日 2013-03-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0967-3334
NCID
収録物識別子タイプ NCID
収録物識別子 AA10890861
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1088/0967-3334/34/3/359
出版者
出版者 Institute of Physics
抄録
内容記述タイプ Abstract
内容記述 Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress. © 2013 Institute of Physics and Engineering in Medicine.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 02:06:48.519627
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3