ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. B. 理工学域; 数物科学類・物質化学類・機械工学類・フロンティア工学類・電子情報通信学類・地球社会基盤学類・生命理工学類
  2. b 10. 学術雑誌掲載論文
  3. 1.査読済論文(工)

A three-dimensional imaging detector based on nano-scale silver-related defects in X- and gamma-ray-irradiated glasses

http://hdl.handle.net/2297/44804
http://hdl.handle.net/2297/44804
95a0bea9-9b45-48f0-944c-292a6be3f6b4
名前 / ファイル ライセンス アクション
ED-PR-KUROBORI-T-02BC01.pdf ED-PR-KUROBORI-T-02BC01.pdf (878.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル A three-dimensional imaging detector based on nano-scale silver-related defects in X- and gamma-ray-irradiated glasses
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kurobori, Toshio

× Kurobori, Toshio

WEKO 7684
研究者番号 90153428

Kurobori, Toshio

Search repository
Yanagida, Yuka

× Yanagida, Yuka

WEKO 13130

Yanagida, Yuka

Search repository
Chen, Yaoqiang

× Chen, Yaoqiang

WEKO 13131

Chen, Yaoqiang

Search repository
書誌情報 Japanese Journal of Applied Physics

巻 55, 号 2, p. 02BC01, 発行日 2016-02-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-4922
NCID
収録物識別子タイプ NCID
収録物識別子 AA12295836
DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.7567/JJAP.55.02BC01
出版者
出版者 応用物理学会 = Japan Society of Applied Physics
抄録
内容記述タイプ Abstract
内容記述 Ag-activated phosphate glass, which is the most commonly known radiophotoluminescent (RPL) material, has the capability to operate not only dosimeters but also two- and three-dimensional (2D and 3D) dose imaging detectors in the same host. This passive detector is based on radiationinduced, optically active nano-scale defects. In this work, the transient-state optical properties of the blue and orange RPL were investigated using a time-resolved spectrum technique for 137Cs and 60Co gamma-ray-irradiated Ag-activated phosphate glass. Specifically, the blue RPL intensity with a decay time of 5 ns as a function of the depth at the vicinity of the surface was systematically examined to clarify an accurate dose distribution within the glass. Moreover, a feasibility study into the use of an RPL Ag-activated phosphate glass detector for fluorescent nuclear track imaging was demonstrated using a confocal fluorescence image microscope for the first time. © 2016 The Japan Society of Applied Physics.
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
関連URI
識別子タイプ URI
関連識別子 http://www.jsap.or.jp/
戻る
0
views
See details
Views

Versions

Ver.1 2023-07-28 01:57:47.968465
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3