WEKO3
インデックスリンク
アイテム
SU-8-based flexible amperometric device with IDA electrodes to regenerate redox species in small spaces.
https://doi.org/10.24517/00009192
https://doi.org/10.24517/0000919237064f31-6ea1-4483-89a5-2018e536f76f
| 名前 / ファイル | ライセンス | アクション |
|---|---|---|
|
|
| Item type | 学術雑誌論文 / Journal Article(1) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2017-10-03 | |||||||||||||||
| タイトル | ||||||||||||||||
| タイトル | SU-8-based flexible amperometric device with IDA electrodes to regenerate redox species in small spaces. | |||||||||||||||
| 言語 | ||||||||||||||||
| 言語 | eng | |||||||||||||||
| 資源タイプ | ||||||||||||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||||||
| 資源タイプ | journal article | |||||||||||||||
| ID登録 | ||||||||||||||||
| ID登録 | 10.24517/00009192 | |||||||||||||||
| ID登録タイプ | JaLC | |||||||||||||||
| 著者 |
Kanno, Yusuke
× Kanno, Yusuke× Goto, Takehito× Ino, Kosuke× Inoue, Kumi Y.× Takahashi, Yasufumi× Shiku, Hitoshi× Matsue, Tomokazu |
|||||||||||||||
| 著者別表示 |
伊野, 浩介
× 伊野, 浩介
× 井上, 久美
× 高橋, 康史
× 珠玖, 仁
× 末永, 智一
|
|||||||||||||||
| 提供者所属 | ||||||||||||||||
| 内容記述タイプ | Other | |||||||||||||||
| 内容記述 | 金沢大学ナノ生命科学研究所 | |||||||||||||||
| 書誌情報 |
Analytical Sciences 巻 30, 号 2, p. 305-309, 発行日 2014-01-01 |
|||||||||||||||
| ISSN | ||||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||||
| 収録物識別子 | 0910-6340 | |||||||||||||||
| NCID | ||||||||||||||||
| 収録物識別子タイプ | NCID | |||||||||||||||
| 収録物識別子 | AA10500785 | |||||||||||||||
| DOI | ||||||||||||||||
| 関連タイプ | isIdenticalTo | |||||||||||||||
| 識別子タイプ | DOI | |||||||||||||||
| 関連識別子 | 10.2116/analsci.30.305 | |||||||||||||||
| 出版者 | ||||||||||||||||
| 出版者 | The Japan Society for Analytical Chemistry = 日本分析化学会 | |||||||||||||||
| 抄録 | ||||||||||||||||
| 内容記述タイプ | Abstract | |||||||||||||||
| 内容記述 | A flexible sensor based on SU-8 photoresist was fabricated and its electrochemical performance was investigated using cyclic voltammetry. The device consisted of interdigitated array (IDA) electrodes on an SU-8 layer. It exhibited a clear electrochemical response during redox cycling of ferrocenemethanol at the IDA electrodes. Since the device was flexible, it could be inserted into a narrow bent space to monitor electrochemical responses. The observed electrochemical behavior was found to be consistent with that predicted by simulations based on redox compound diffusion. | |||||||||||||||
| 権利 | ||||||||||||||||
| 権利情報 | Copyright © 2014 by The Japan Society for Analytical Chemistry | |||||||||||||||
| 著者版フラグ | ||||||||||||||||
| 出版タイプ | VoR | |||||||||||||||
| 出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||||||||||||
| 関連URI | ||||||||||||||||
| 識別子タイプ | URI | |||||||||||||||
| 関連識別子 | http://www.jsac.jp/ | |||||||||||||||
| 関連URI | ||||||||||||||||
| 識別子タイプ | URI | |||||||||||||||
| 関連識別子 | https://www.jstage.jst.go.jp/browse/analsci | |||||||||||||||