Micron size GMR magnetic sensor with needle structure

http://hdl.handle.net/2297/48634
http://hdl.handle.net/2297/48634
feb411b2-677e-48bb-b7ad-04c6c540a1a0
名前 / ファイル ライセンス アクション
TE-PR-YAMADA-S-997.pdf TE-PR-YAMADA-S-997.pdf (2.8 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-10-03
タイトル
タイトル Micron size GMR magnetic sensor with needle structure
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Yamada, Sotoshi

× Yamada, Sotoshi

WEKO 11069
e-Rad 80019786
研究者番号 80019786

Yamada, Sotoshi

Search repository
Haraszczuk, R.

× Haraszczuk, R.

WEKO 13987

Haraszczuk, R.

Search repository
Kakikawa, Makiko

× Kakikawa, Makiko

WEKO 189
e-Rad 10359713
金沢大学研究者情報 10359713
研究者番号 10359713

Kakikawa, Makiko

Search repository
Hoang, H.

× Hoang, H.

WEKO 13988

Hoang, H.

Search repository
書誌情報 AIP Conference Proceedings

巻 1430, 号 31, p. 997-1004, 発行日 2012-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0094-243X
NCID
収録物識別子タイプ NCID
収録物識別子 AA00502977
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1063/1.4716331
出版者
出版者 American Institute of Physics
抄録
内容記述タイプ Abstract
内容記述 The work presents inimitable shaped needle type probe with spin valve giant magnetoresistance (SV-GMR) elements. Sensitive elements with 75 μm width are connected in the Wheatstone bridge structure. The length of the needle is 20-30 mm and its cross section is square. The magnetic sensor probe has the advantage of micron order spatial resolution. The needle type probe works as a gradient meter which concurrently suppresses the influence of externally applied field and detects magnetic fields emanating from nano or micro order size sources. Sensing elements present high sensitivity 260 μV/μT and are capable of detecting the magnetic fields in order of few nT. SV-GMR elements present flat amplitude and phase characteristics in wide frequency range. The novel characteristicsof the probe allow it to be utilized in detection of the in-phase and out of phase signal components. An additional merit of this design is extremely small liftoff height between sensing element and the source of magnetic field. The SV-GMR elements are isolated only by very thin protection layer (a few μm), that gives opportunity to apply the probe in biological (in vivo) experiments, and in non destructive evaluation of current detection. The needle shape allows the sensing element toapproach the examined materials in a distance of few ten μm. © 2012 American Institute of Physics.
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views