WEKO3
インデックスリンク
アイテム
{"_buckets": {"deposit": "c12bd2da-371c-4a88-9a05-d763e64cdc31"}, "_deposit": {"created_by": 3, "id": "14226", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "14226"}, "status": "published"}, "_oai": {"id": "oai:kanazawa-u.repo.nii.ac.jp:00014226", "sets": ["1134"]}, "author_link": ["24450", "24449", "646", "24447", "24446", "24448"], "item_4_biblio_info_8": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-04-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "630", "bibliographicPageStart": "625", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "Physica Medica"}]}]}, "item_4_description_21": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. Methods: To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). Results: The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of \u003c1.0 was almost equal to the gantry rotation time, whereas with pitch factor of \u003e1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/. P = 0.285/1.5) and 0.074. s (R/. P = 0.285/3.2), and the maximum TR values of the 64. ×. 0.5- and 160. ×. 0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/. P = 0.275/1.375) and 0.195. s (R/. P = 0.3/0.6), respectively. Conclusion: Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. © 2016 Associazione Italiana di Fisica Medica.", "subitem_description_type": "Abstract"}]}, "item_4_publisher_17": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Associazione Italiana di Fisica Medica / Elsevier"}]}, "item_4_relation_12": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.ejmp.2016.02.015", "subitem_relation_type_select": "DOI"}}]}, "item_4_relation_28": {"attribute_name": "関連URI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://www.elsevier.com/locate/issn/11201797", "subitem_relation_type_select": "URI"}}]}, "item_4_rights_23": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright © Elsevier (CC-BY NC ND)"}]}, "item_4_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11064306", "subitem_source_identifier_type": "NCID"}]}, "item_4_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1120-1797", "subitem_source_identifier_type": "ISSN"}]}, "item_4_version_type_25": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hara, Takanori"}], "nameIdentifiers": [{"nameIdentifier": "24446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Urikura, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "24447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichikawa, Katsuhiro"}], "nameIdentifiers": [{"nameIdentifier": "646", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://kaken.nii.ac.jp/ja/search/?qm=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "金沢大学研究者情報", "nameIdentifierURI": "http://ridb.kanazawa-u.ac.jp/public/detail.php?kaken=40402630"}, {"nameIdentifier": "40402630", "nameIdentifierScheme": "研究者番号", "nameIdentifierURI": "https://nrid.nii.ac.jp/nrid/1000040402630"}]}, {"creatorNames": [{"creatorName": "Hoshino, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "24448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishimaru, Eiji"}], "nameIdentifiers": [{"nameIdentifier": "24449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Niwa, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "24450", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-10-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ME-PR-ICHIKAWA-K-625.pdf", "filesize": [{"value": "628.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 628100.0, "url": {"label": "ME-PR-ICHIKAWA-K-625.pdf", "url": "https://kanazawa-u.repo.nii.ac.jp/record/14226/files/ME-PR-ICHIKAWA-K-625.pdf"}, "version_id": "b7a27274-0d81-4186-b2ce-2256c0e4de75"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Gantry rotation time", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Helical acquisition mode", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pitch factor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Temporal resolution", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method"}]}, "item_type_id": "4", "owner": "3", "path": ["1134"], "permalink_uri": "http://hdl.handle.net/2297/45574", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-10-03"}, "publish_date": "2017-10-03", "publish_status": "0", "recid": "14226", "relation": {}, "relation_version_is_last": true, "title": ["Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method"], "weko_shared_id": -1}
Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method
http://hdl.handle.net/2297/45574
http://hdl.handle.net/2297/45574fd4436f4-edd1-4c04-bbb5-bdcc5585b14b
名前 / ファイル | ライセンス | アクション |
---|---|---|
ME-PR-ICHIKAWA-K-625.pdf (628.1 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-10-03 | |||||
タイトル | ||||||
タイトル | Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Hara, Takanori
× Hara, Takanori× Urikura, Atsushi× Ichikawa, Katsuhiro× Hoshino, Takashi× Nishimaru, Eiji× Niwa, Shinji |
|||||
書誌情報 |
Physica Medica 巻 32, 号 4, p. 625-630, 発行日 2016-04-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1120-1797 | |||||
NCID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11064306 | |||||
DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejmp.2016.02.015 | |||||
出版者 | ||||||
出版者 | Associazione Italiana di Fisica Medica / Elsevier | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. Methods: To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor (P) and gantry rotation time (R). Results: The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of <1.0 was almost equal to the gantry rotation time, whereas with pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 (R/. P = 0.285/1.5) and 0.074. s (R/. P = 0.285/3.2), and the maximum TR values of the 64. ×. 0.5- and 160. ×. 0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 (R/. P = 0.275/1.375) and 0.195. s (R/. P = 0.3/0.6), respectively. Conclusion: Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. © 2016 Associazione Italiana di Fisica Medica. | |||||
権利 | ||||||
権利情報 | Copyright © Elsevier (CC-BY NC ND) | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
関連URI | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.elsevier.com/locate/issn/11201797 |